If you want to deactivate this function set command without parameter – tm. XXppppINFOSMS without further parameters.

4.8. SMSINT – Interval for Dispatch of SMS Messages about Operation

Interval for sending regular SMS messages to INFOSMS number, which include time of operation, can be set:

Command

XXppppSMSINTVn (interval of one day is set from production)

 

*1)

 

 

ppppFour digits of current PIN

Number

Number from 1 to 30. It is interval for sending successive

 

message about operation.

*1) The space is between key word of command „SMSINT“ and value of parameter „n“

4.9. ALARMSMS – Alarm SMS Messages

When one of 8 inputs is activated GB 051 allows in addition to phone call to common ACALL number also sending one of 8 prepared texts of SMS message to two cell phone numbers.

Change of texts of SMS messages:

 

Command *1)

 

 

Initial set-up

 

 

Input

 

Order on the

 

 

 

 

 

 

terminal

 

 

 

 

 

 

 

 

 

board

 

XXppppSMSTXT1V“text“

 

ALARM1

 

IO1

1

 

XXppppSMSTXT2V“text“

 

ALARM2

 

IO2

2

 

XXppppSMSTXT3V“text“

 

ALARM3

 

IO3

3

 

XXppppSMSTXT4V text“

 

ALARM4

 

IO4

4

 

XXppppSMSTXT5V“text“

 

ALARM5

 

IO5

5

 

XXppppSMSTXT6V“text“

 

ALARM6

 

IO6

6

 

XXppppSMSTXT7V“text“

 

ALARM7

 

IO7

8

 

XXppppSMSTXT8V“text“

 

ALARM8

 

IO8

9

 

pppp

 

Four digits of current PIN

 

 

text

 

4 - 144 digits, always put in quotes, ?=question

*1) The space is between key word of command “SMSTXT” and “text”

Change of numbers for sending ALARM SMS messages

Text of SMS message No. 1, 2, 3, 4, 5, 6, 7 or 8 will be sent by activation of input No. 1, 2, 3, 4, 5, 6, 7 or 8 (by connection with terminal No. 7 – ground) on terminal board of GB 051. Each prepared text of SMS message of particular input can be sent to two cell phone numbers.

No number is activated from production. These numbers can be set:

14

Image 14
Contents Level Dear Customers Table of Contents GSM Remote Supervision GB Product Description Description of Function Contents of Delivery Wiring and connecting the GSM Remote Supervision unit Inserting the SIM Card and Connecting to the Cell Phone Recommended linkage of outputs Recommended linkage of inputs0000 Is the key word of the commandXX0000PINVpppp PINOccasional short flash Indication by LEDSlow regular flashing Quick flashesPIN in GSM Remote Supervision Change of PIN CommandSpace follows Parameter Example Reset of GSM Remote SupervisionCommand XXppppRESET Pppp Four digits of current PIN InitializationInit Re-initialization of Values Set from Production Command XXppppINIT Pppp Four digits of current PINCommand Pppp Icall Regular Calling Free of ChargeAcall Automatic Alarm Calling Infosms Sending of Information Messages about OperationChange of numbers for sending Alarm SMS messages Alarmsms Alarm SMS MessagesCommand *1 Initial set-up Input Order on Terminal Board TextIO3 IO1IO2 IO4List Detection of Set-up Callback Monitoring of Protected AreaOperation during Failure of External Power Supply Programming from PCList of Programming Commands Control SMS Messages Command XXpppp Range SetOutputs of SMS messages No Basic Technical ParametersInputs of SMS messages No GSM networkGuarantee Certificate Guarantee Conditions Statement of Consensus Page GB 051@1.02 Level