E. IGNITION SYSTEM WIRING

This gas fireplace is equipped with an electronic igni- tion system which operates on a 6 volt system.

This appliance requires 240 VAC to be wired to the factory installed junction box. Check factory installed power cord for damage before using.

CAUTION

Label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock Risk

Replace damaged wire with type 105O C rated wire.

Wire must have high temperature insulation.

FLAME SPARKER/

 

SENSOR

VALVE

 

 

REMOTE

 

 

CONTROL

 

 

ANT.

 

 

ON/OFF

 

PILOT

WALL SWITCH

 

 

IGNITION

 

IGNITION MODULE

MODULE

 

(6V)

 

6VDC

 

 

 

 

GROUND

 

NEUTRAL

 

HOT

BATTERY PORT

 

 

 

 

PLUG IN

ON/OFF

THERMOCOUPLE

 

BLOCK

 

SWITCH

(CONNECTED TO

 

 

BACK OF VALVE)

 

 

VALVE

 

GAS LINE

 

 

CONNECTED TO

 

 

BACK OF VALVE

 

 

FIGURE 1.29

 

 

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

19

Page 19
Image 19