STRAIGHT OUT HORIZONTAL FLUE SYSTEM Figure 1.7 shows straight out horizontal flue systems approved for use on this model.

H

H

MIN. RUN

MAX. RUN

13.1" (331mm)

24" (610mm)

H

 

FIGURE 1.7 Straight Out Horizontal Flueing

ELBOWS

The flue systems installed on this gas heater may also include one (1), two (2), or three (3) 90 - degree elbow assemblies.

Figures 1.8 through 1.14 and their corresponding tables show examples of flue configurations using elbows. The relationships of vertical rise to horizon- tal run in flue configurations using elbows MUST be strictly adhered to.

V

 

H

 

1´ MIN. (0.30 M)

2´ MAX. (0.61 M)

2´ MIN. (0.61

M)

4´ MAX. (1.22 M)

3´ MIN. (0.91

M)

6´ MAX. (1.83

M)

4´ MIN. (1.22

M)

8´ MAX. (2.44

M)

24´ MAX. (7.32 M)

8´ MAX. (2.44

M)

 

 

 

 

V

H

FIGURE 1.8 Flueing with One 90° Elbow

ONE (1) 90-DEGREE ELBOW

Figures 1.8 and 1.9 show an installation using one (1) 90-degree elbow. Dimension V is listed as MINIMUM vertical dimensions and dimension H is listed as corre- sponding MAXIMUM horizontal dimensions.

TWO (2) 90-DEGREE ELBOWS

Figures 1.10 and 1.11 show examples of possible in- stallations using two (2) 90-degree elbows. Dimension V is listed as MINIMUM vertical dimensions, dimen- sion H is listed as MAXIMUM beginning horizontal di- mensions, and dimension H+H1 is listed as correspond- ing TOTAL MAXIMUM horizontal dimensions.

THREE (3) 90-DEGREE ELBOWS

Figures 1.12 through 1.14 show examples of possible installations using three (3) 90-degree elbows. Dimen- sions V are listed MINIMUM first vertical dimensions and dimensions H are listed as beginning MAXIMUM horizontal dimensions. Dimensions H+H1 and H+H1+H2 are listed as TOTAL MAXIMUM horizontal dimensions. Dimensions V+V1 are listed as TOTAL MAXIMUM ver- tical dimensions.

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

9