V (FT.)

H (FT.)

1' MIN. (0.30 M)

4' MAX. (1.22 M)

2' MIN. (0.61 M)

8' MAX. (2.44 M)

3' MIN. (0.91 M)

12' MAX. (3.66 M)

4' MIN. (1.22 M)

16' MAX. (4.88 M)

V+H= 24’ MAX. (7.32 M)

 

 

 

H

V

NOTE: A 6-inch (152mm) section of straight pipe must need to be attached to the fireplace before a 90o elbow.

FIGURE 1.9 Flueing with One 90° Elbow

H1

V

 

 

H

 

 

 

V FT.)

H (FT.)

H+H1 (FT.)

1' MIN. (0.30 M)

2' MAX. (0.61 M)

4' MAX. (1.22 M)

2' MIN. (0.61 M)

2' MAX. (0.61 M)

8' MAX. (2.44 M)

3' MIN. (0.91 M)

4' MAX. (1.22 M)

12' MAX. (3.66 M)

4' MIN. (1.22 M)

6' MAX. (1.83 M)

16' MAX. (4.88 M)

20' MAX. (6.10 M)

6' MAX. (1.83 M)

16' MAX. (4.88 M)

 

 

 

FIGURE 1.10 Flueing with Two 90° Elbows

10

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

Page 10
Image 10
Hearth and Home Technologies Heat & Glo, 6000TRSI-AUC manual Flueing with One 90 Elbow +H 1 FT