C.FLUE SYSTEM APPROVALS AND INSTALLATIONS

MODEL FLUE TERMINATION APPROVALS

6000TRSI-AUC DVP-TRAP2, DVP-TVHW

TABLE 1

This model is approved to use DVP-Series flue pipe components. A DVP-TRAP2Termination Cap must be used to terminate flue systems in a horizontal position. A DVP-TVHWvertical Termination Cap must be used to terminate flue systems in a vertical position.

Figures 1.7 through 1.14 show the flue systems ap- proved for these models. Approved flue system compo- nents are labeled for identification. NO OTHER FLUE SYSTEMS OR COMPONENTS MAY BE USED. De- tailed installation instructions are included with each flue termination kit and should be used in conjunction with this manual.

WARNING: THIS GAS APPLIANCE AND FLUE AS- SEMBLY MUST BE FLUED DIRECTLY TO THE OUT- SIDE AND MUST NEVER BE ATTACHED TO A CHIM- NEY SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. EACH GAS APPLIANCE MUST USE A SEPARATE FLUE SYSTEM-COMMON FLUE SYS- TEMS ARE PROHIBITED.

CAUTION: UNDER NO CONDITION SHOULD COM- BUSTIBLE MATERIAL BE CLOSER THAN 3 INCHES (2 1/2 INCHES AT WALL FIRESTOPS) FROM THE TOP OF THE 8 INCH PIPE OR 1- INCH TO THE SIDES AND THE BOTTOM FOR HORIZONTAL SECTIONS OF THIS FLUE SYSTEM. VERTICAL SECTIONS OF THIS SYSTEM REQUIRE A MINIMUM OF 1 INCH CLEARANCE TO COMBUSTIBLE MATERIALS ALL AROUND THE 8 INCH PIPE.

For alternative installations, other than depicted, con- tact your dealer for further information.

Refer to Figure 1.4 for required clearances to flue ter- minals.

VERTICAL FLUE RESTRICTOR

If the heater installation requires a vertical flue exceed- ing 4.5m above the unit with no horizontal flue or el- bows a vertical flue restrictor must be installed (see

Figure 1.5).

RESTRICTOR

PLATE

FIGURE 1.5

STRAIGHT UP VERTICAL FLUE SYSTEM

Figure 1.6 shows straight up vertical flue system ap- proved for use on this model.

CAP

V

MAX. RUN

36 FT.

(10.97m)

FIGURE 1.6

8

Heat & Glo • 6000TRSI-AUC2078-900 Rev. G • 12/06

Page 8
Image 8
Hearth and Home Technologies Heat & Glo, 6000TRSI-AUC manual Flue System Approvals and Installations, 10.97m