Texas Instruments 3000 MCU manual Check Components

Page 13

SpectraLink Corporation

T1 Remote Module Installation

 

Link WTS – Link 3000 MCU

2.3Check Components

The following items should be at the installation site.

Link 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies depending on the size of the system.

Grounding Strap – (in the Link WTS Administration Kit, MKA320) – to protect cards from electrostatic discharge.

Expansion Shelf Controller Card – (CSC300) - one card for each Expansion Shelf. This card is installed in Slot 2.

T1 Remote Module– (CRC301) - one card for the remote site and one card for the local site for EACH remote shelf.

Cables – two 12 foot RJ-45 cables with each Expansion Shelf Controller (CSC300). RJ-45 cable to connect multiple shelves (one for each shelf).

Interface Modules – the correct number and type of Interface Modules to connect the Wireless Telephones and the Base Stations to the telphone system. Interface Modules can support analog (CPA316), Universal digital (CPU316), Mitel (CPM316), Executone (CPB316), Panasonic (CPP316), and select four-wire (CPF316) interfaces.

Part Number: 72-0059-06-E.doc

Page 13

Image 13
Contents T1 Remote Module Installation Trademark Information Part Number 72-0059-06-E.doc UL Information FCC Information Industry Canada IC Notice Table of Contents Contacting SpectraLink About This DocumentIcons Used in this Document Location a Local Remote Installation Steps Overview Required Materials Provided by Customer Site PreparationChannel Service Unit CSU T1 Configuration RequirementsCheck Components Connect Intershelf Junction Panel Install T1 Remote Module at Local SiteNetwork Clocked T1 Facilities Alarm Install Shelves Install System at Remote SiteSurvey Site Install Cards Connect Power to ShelvesConnect Multiple Remote Shelves Connect Cables to T1 Remote ModuleAlarm Connect Demarc Block RJ-21 Cables to Interface Modules Configure Remote Shelf Configure Remote SystemTest System Master Clock ConfigurationSite Certification Installation Forms Shelf Number Interface Module Base Station Location FormShelf Interface Module Extension Assignments WorksheetMonday through Friday, 7 AM to 6 PM MT Site Preparation ChecklistQty Customer Acceptance FormCustomer Acceptance Form Index