Texas Instruments 3000 MCU manual T1 Configuration Requirements, Channel Service Unit CSU

Page 12

SpectraLink Corporation

T1 Remote Module Installation

 

Link WTS – Link 3000 MCU

2.2T1 Configuration Requirements

T1 circuits will connect expansion shelves directly to the System Controller shelf via the SpectraLink provided Intershelf Junction Panel. The Intershelf Junction Panel is always co-located with the system controller shelf.

The following configuration requirements apply to the T1 lines connecting the Link 3000 MCU local and remote shelves.

All T1 circuits for networking the Link WTS must be Extended Superframe Format (ESF).

T1 circuits must be a full T1 (not fractional).

T1 circuits must be 64Kbps (not 56Kbps) per channel.

Line coding for the T1 circuits must be Bipolar 8-bit Zero Substitution (B8ZS).

T1 circuits should be terminated as close to the Link 3000 MCU shelves as possible, at both the System Controller site and the Expansion Controller site(s).

One or two T1 circuits are required per remote Link 3000 MCU Expansion Shelf.

One T1 circuit is required for the first five Interface Module cards in a Remote Expansion shelf.

Two T1 circuits are required for 6 or more Interface Module cards installed in the remote expansion shelf. Note that 1 - 10 Interface Module cards may be installed in any expansion shelf.

The T1 circuit must be activated and verified to be in proper working order at least one week in advance of the networked Link WTS scheduled installation.

Channel Service Unit (CSU)

A Channel Service Unit (CSU) must be installed at each end of the T1 circuit.

The ADC Kentrox T-SERV II or other comparable CSU models are satisfactory.

From the CSU, the T1 circuit must be provided to the SpectraLink system on an RJ-48C modular connector.

The CSU must have an independent power supply, per manufacturer specifications.

Part Number: 72-0059-06-E.doc

Page 12

Image 12
Contents T1 Remote Module Installation Trademark Information Part Number 72-0059-06-E.doc UL Information FCC Information Industry Canada IC Notice Table of Contents About This Document Contacting SpectraLinkIcons Used in this Document Location a Local Remote Installation Steps Overview Site Preparation Required Materials Provided by CustomerT1 Configuration Requirements Channel Service Unit CSUCheck Components Install T1 Remote Module at Local Site Connect Intershelf Junction PanelNetwork Clocked T1 Facilities Alarm Install System at Remote Site Install ShelvesSurvey Site Connect Power to Shelves Install CardsConnect Cables to T1 Remote Module Connect Multiple Remote ShelvesAlarm Connect Demarc Block RJ-21 Cables to Interface Modules Configure Remote System Configure Remote ShelfMaster Clock Configuration Test SystemSite Certification Installation Forms Base Station Location Form Shelf Number Interface ModuleExtension Assignments Worksheet Shelf Interface ModuleSite Preparation Checklist Monday through Friday, 7 AM to 6 PM MTCustomer Acceptance Form QtyIndex Customer Acceptance Form