7.3Site Preparation Checklist

If upon arrival the SpectraLink installer determines that the pre-installation work has not been completed correctly, the installer has two options: 1) the installer can leave the site and reschedule the installation when the action items have been completed or corrected, or 2) the installer can assist in preparing the site, and thus spend additional time installing the system. Because of the additional cost incurred by SpectraLink in executing either option, the customer will be billed for the additional time at our standard hourly rate plus expenses.

Please be sure the following items are completed.

MCU location prepared. Typically the MCU is installed in the telephone equipment room. This location must have sufficient rack or backboard space and power available.

Two-pair wires are run to each of the Base Station locations as designated on the building floor plans. Use Level 3 cable for lengths up to 3,500'; Level 4 for lengths up to 6,000'.

The Base Station cables are terminated with RJ-45 crimp-on plugs at the designated locations.

One (or two) cross-connect block(s) are installed for every Interface Module and connected with a 25-pair Telco cable terminated with an RJ-21 male connector at the MCU location.

The Base Station cables are terminated at the appropriate cross-connect blocks.

Analog or digital ports, one per Wireless Telephone, from the switch are terminated at the appropriate cross-connect block and the block is labeled with the extensions.

A dedicated dial line (MB) is available with an RJ-11 jack for the diagnostic modem.

An IBM-compatible PC is available to serve as the Operator’s Console for system administration.

A system administrator is designated for the SpectraLink system. This person should be present for the installation. The SpectraLink installer will provide system training to the system administrator on the day following the installation.

When this checklist is completed please sign, date, and fax to:

(Install Coordination 303-449-7016)

Signature: _______________________________________ Date: _________________

If you have any questions regarding the installation procedure, please call:

SpectraLink Customer Support Hotline 1-800-775-5330

(Monday through Friday, 7 AM to 6 PM MT).

Part Number: 72-0059-06-E.doc

Page 28

Image 28
Contents T1 Remote Module Installation Trademark Information Part Number 72-0059-06-E.doc UL Information FCC Information Industry Canada IC Notice Table of Contents Contacting SpectraLink About This DocumentIcons Used in this Document Location a Local Remote Installation Steps Overview Site Preparation Required Materials Provided by CustomerT1 Configuration Requirements Channel Service Unit CSUCheck Components Install T1 Remote Module at Local Site Connect Intershelf Junction PanelNetwork Clocked T1 Facilities Alarm Install Shelves Install System at Remote SiteSurvey Site Connect Power to Shelves Install CardsConnect Cables to T1 Remote Module Connect Multiple Remote ShelvesAlarm Connect Demarc Block RJ-21 Cables to Interface Modules Configure Remote System Configure Remote ShelfMaster Clock Configuration Test SystemSite Certification Installation Forms Base Station Location Form Shelf Number Interface ModuleExtension Assignments Worksheet Shelf Interface ModuleSite Preparation Checklist Monday through Friday, 7 AM to 6 PM MTCustomer Acceptance Form QtyIndex Customer Acceptance Form