Keys Fitness T240, T260 Quick Troubleshooting Check List, Problem Possible CAUSE/SOLUTION

Page 29

Quick Troubleshooting Check List

If you experience a problem during the normal operation of the T240 – T260, use the following troubleshooting table below. If you are unfamiliar or uncertain with basic diagnostic maintenance procedures, contact your Authorized Bodyguard® Dealer for diagnostics or repair of your T240 – T260.

Table 2

PROBLEM

POSSIBLE CAUSE/SOLUTION

• Computer will not light

• Unit is not plugged in. – Plug unit in.

up when power

• Power cord. – Check that power cord is functional; replace if necessary.

is turned ON.

• Circuit breaker. – Reset the breaker.

 

 

• Damaged motor circuit board. – Contact your Bodyguard® Dealer.

 

• The belt is over tensioned. – Perform Belt Alignment.

 

• The wires are not connected. – Remove the cover and connect the wires properly.

 

 

• Belt doesn’t turn.

• Magnetic key is not in place. – Insert the magnetic key.

 

 

• Elevation does not

• It is not calibrated. – Perform Elevation Calibration.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Connect the elevation wire to the circuit board.

 

 

• Motor drive does not

• It is not calibrated. – Perform Motor Check.

respond properly.

• The wire is not connected on the motor circuit board. –

 

 

Motor wiring harness needs to be connected to the lower board.

 

 

• Motor turns backwards.

• The wires are reversed on the circuit drive. –

 

Contact your Bodyguard® Dealer.

• Computer key(s) not

• Keypad may have damage from liquid penetrating seal. –

responding to touch,

Contact your Bodyguard® Dealer.

or sticking.

• Excessive amount of cleaning solution used. –

 

Use mild cleanser on damp cloth only when cleaning console and unit.

 

 

• Squeaking noise from

• Poly V-belt slipping. – Contact your Bodyguard® Dealer.

the motor.

• Motor brush noise excessive. – Contact your Bodyguard® Dealer.

• Belt tracks left

• Uneven floor. – Move the treadmill to an even floor.

and right.

• Rear roller not adjusted for sloped floor. –

 

The rear roller needs to be adjusted. Perform Belt Alignment.

 

 

• Speed is not constant or

• The drive motor is not calibrated. – Perform Motor Check.

seems too fast or slow.

• The tension on the motor drive is too excessive. –

 

Remove tension on the running belt. Perform Belt Alignment.

 

 

• Can’t get out at the end

• Elevation is not calibrated. – Perform Elevation Calibration.

of a program.

 

 

 

• Error log

• See table 3

 

 

29

Image 29
Contents T240 T260 Contents For Your Personal Safety IMPORTANTImportant SafetySAFETYNoticeNOTICEKnow Your Heart Rate Electrical InformationResponsibility of the User T240 T260 Limited WarrantyGetting to know the T240 T260 Computer display Monitor OperatiOperating yourKeys Scanning FeatureSaving an Exercise custom programs Pausing During an ExerciseAccess to Settings Menu Settingtti Up the Computer tto Your EnvironmentLanguage Feature Viewing Exercise ParametersUser Identification Feature Weight Unit FeatureActivate User Create UserEdit User Reset StatisticsView Statistics Delete UserTime, Distance or Calories Feature Distance Unit FeatureWarm Up and Cool Down Feature Table of minimum and maximum valuesHeart Rate Access Options Feature Heart Rate Control Options FeatureSpeed Limits Beeper FeatureBig Number Option Learn Program T260Program Levels Heart Rate Recovery T260 onlyExercisExercise Programs Hill Climb Program T260 only JustGo ProgramManual Program Track Program T260 only Speed Run Program T260 onlyHeart Rate Control Program HRC and Weight Loss Program Walk Program Cardiovascular ProgramMemory & Learn Programs Changing Your Target Heart Rate in a Program Heart Rate Access FeatureHow to Use Heart Rate Access Usingsi a Heart Rate Receiveri r Problem Possible Cause Solution Access to Diagnostics menuEprom test Nvram TestKeypad Test Display TestBelt Alignment Beeper testHeart Rate System Test Elevation Calibration Motor CheckError log Safety Key testStatistics Speed sensor testGeneral Care Maintenance InformationInfor ationMaintenance Deck Surface Belt and Running Deck Running BeltProblem Possible CAUSE/SOLUTION Quick Troubleshooting Check ListThank You for Purchasing a Bodyguard T240 T260 Error CodesInterference limits requirements North America Safety requirements North AmericaInternational Designed and Engineered in Canada