Precor c954 owner manual Maintenance, Cleaning the Equipment, Aligning the Running Belt

Page 42

C O M M E R C I A L P R O D U C T S D I V I S I O N

Maintenance

The C956 or C954 requires little maintenance to keep it running smoothly and efficiently. However, you, as club manager or owner, are responsible for typical maintenance tasks such as, cleaning the unit to keep it free from dust and dirt accumulation. If you fail to maintain the treadmill as described below, it could affect or void the Precor limited warranty.

CLEANING THE EQUIPMENT

DANGER — T O REDUCE THE RISK OF ELECTRICAL SHOCK, ALWAYS UNPLUG THE UNIT FROM ITS POWER SOURCE BEFORE CLEANING IT OR PERFORMING ANY MAINTENANCE TASKS.

Most of the working mechanisms are protected inside the treadmill’s hood and solid base. However, for efficient operation, the treadmill relies on low friction. To keep the friction low, the treadmill must be as clean as possible.

It is recommended that the running bed and belt be cleaned daily. Use a damp, soft cloth to clean the staging platform, running bed and between the belt and running bed surface as far as you can easily reach. This removes any dust or dirt which might affect the smooth operation of the unit.

CAUTION: Never pour water or spray liquids on the display console, hand- rails, or treadmill. Allow the treadmill to dry completely before using.

Periodically, clean the treadmill’s frame, display console, handrails and running belt with a dampened (not dripping wet), clean cloth using a diluted solution of Simple Green®.To clean the grooves on the belt, use a soft nylon scrub brush.Vacuum the floor underneath the unit every week to prevent the accumulation of dust and dirt.

The Precor Heart Rate equipment requires little maintenance beyond keeping it dust free. Dampen a sponge or soft cloth in mild soap and water to wipe the POLAR® chest strap. Dry the surface thoroughly with a clean towel.

ALIGNING THE RUNNING BELT

The correct alignment of the running belt is critical to the smooth operation of the treadmill.The belt is properly aligned at the factory. However, during shipping and handling or by use on an uneven surface, the belt may move off center and require a few simple adjustments.

Before aligning the running belt, check its operation by following the procedure in Checking the Alignment of the Running Belt on page 19. If you determine that the belt needs alignment, follow the instructions here.

CAUTION: Special care must be taken when aligning the running belt.Turn OFF the treadmill while adjusting or working near the rear roller. Remove any loose clothing and tie back your hair. Be very careful to keep your finger or any other object clear of the belt and rollers, especially in front of the roller and behind the deck. The treadmill will not stop immediately if an object becomes caught in the belt or rollers.

Realigning the belt takes a few simple adjustments. If you are unsure about this procedure, call Precor Customer Support (see Obtaining Service on page 7.)

page 42

Image 42
Contents C954 C956 Important Safety Instructions Safety Approval Grounding InstructionsTable of Contents Maintenance Exercising on the TreadmillCourses Radio Frequency Interference RFI European ApplicationsPer FCC rules, changes or modifications to Obtaining Service About this ManualUnpacking the Treadmill Standard EquipmentOther Equipment Hardware KIT Assembly Instructions Setting Up the TreadmillInstallation Requirements Additional Tools NeededDiagram M M E R C I a L O D U C T S V I S I O N Attach Connect Secure Diagram 13 Handrail alignment and installation Replace Turning the Unit on and OFF Checking the Alignment of the Running Belt If the running belt ThenChanging the Club Settings Club InformationDisplay key functions within the Club Custom Mode Selecting the LanguageDetermining the Units of Measure Determining the Club Speed Limit Setting a Workout Time LimitSetting a Pause Time Limit To 20.0 kphSpeed or Incline or Enter Stop or Reset Changing the C956 Custom CoursesCustom Course Program Keys Speed , Speed Using Csafe Standard EquipmentReset User ID Entry Program KeysFeatures on the Display Console C56/C954 DisplayTOP Display Windows Upper Display C956 onlyM M E R C I a L P R O D U C T S D I V I S I O N Keys on the Display Console Keypad TipsM M E R C I a L P R O D U C T S D I V I S I O N Quick Start Default Values Prompts Default ValuePress Quick Start at Following occurs Exercising on the Treadmill Using the Security ClipPAUSE, Cool DOWN, Summary and Exit Features A course You press This is what happensCool down You press This is what happens Pause mode You press This is what happensSpeed At theWorkout Summary banner You press This is what happensQuick Steps to Working OUT Workout TipsCooling Down After a Workout Heart Rate Feature Using the Smart Rate FeatureCourses Manual Mode and the Quick Start KEY WeightC956 Track Course C956 Preprogrammed CoursesC956 Interval Course C956 Custom Courses C956 Random CourseTo use the interval course, take the following steps C956 Heart Rate Course C956 Weight Loss Course C956 GOAL-BASED CoursesMaintenance Cleaning the EquipmentAligning the Running Belt Align the running belt Storing the Polar Chest Strap Servicing the TreadmillLong Term Storage C956 C954 C956 C954 C956 C954 C956 C954 C956 C954 C956 C954 C956 C954 Page Page Page Commercial Equipment Limited Warranty Warranty Registration Card Product Specifications