ProForm 485 CS manual Troubleshooting, Compatible with GFCI-equipped outlets

Page 25

TROUBLESHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please see the front cover of this manual. PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor

is plugged into a properly grounded outlet (see page 13). Use only a single-outlet surge suppres-

sor that meets all of the specifications described on page 13. IMPORTANT: The treadmill is not

compatible with GFCI-equipped outlets.

 

 

b. After the power cord has been plugged in, make sure that the key is inserted into the console.

c. Check the reset/off circuit breaker located on the

c

 

treadmill frame near the power cord. If the switch

 

protrudes as shown, the circuit breaker has

Tripped

Reset

tripped. To reset the circuit breaker, wait for five

minutes and then press the switch back in.

Position

Position

PROBLEM: The power turns off during use

 

 

SOLUTION: a. Check the reset/off circuit breaker (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.

c. Remove the key from the console. Reinsert the key into the console.

d. If the treadmill still will not run, please see the front cover of this manual.

PROBLEM: The console displays remain lit when you remove the key from the console

SOLUTION: a. The console features a display demo mode, designed to be used if the treadmill is displayed in a

store. If the displays remain lit when you remove the key, the demo mode is turned on. To turn off

the demo mode, hold down the Stop button for a few seconds. If the displays are still lit, see THE

INFORMATION MODE on page 22 and turn off the demo mode.

 

 

PROBLEM: The displays of the console do not function properly

 

 

 

SOLUTION: a. Remove the key from the console and UNPLUG

a

73

 

THE POWER CORD. With the help of a second

 

person, carefully tip the Uprights (73, 78) down.

 

 

 

There may be two M4.2 x 16mm Screws (12) in the

 

 

 

bottom of the Belly Pan (69). If there are, remove

 

 

 

them. Note: A Phillips screwdriver with a shaft at

78

 

69

least 5 in. (13 cm) long is required.

 

 

 

12

12

 

 

 

25

Image 25
Contents Model No. PFTL95908.0 Serial No QUESTIONS?Please do not Contact Mon.-Fri a.m.-6 p.m. MST Sat a.m.-4 p.m. MSTTable of Contents Pulse sensor is not a medical device Important PrecautionsCord immediately after use, before cleaning Before YOU Begin Assembly Page Bolts yet Tighten the Nut the Wheel must turn freely Not fully fold the Frame yetDo not fully tighten the Bolts yet Screws for stepPage Fore tightening any of them That no wires are pinchedMake sure that no wires are pinched HOW to Plug in the Power Cord Operation and AdjustmentPRE-LUBRICATED Walking Belt Features of the Console Console DiagramSelect the user mode HOW to Turn on the PowerSet the date and time Select a default user settingHOW to USE the Manual Mode HOW to Identify Yourself AS User 1 or UserSelect the manual mode Insert the key into the consoleMeasure your heart rate if desired Select a personal trainer workout HOW to USE a Personal Trainer WorkoutHOW to View the Fitness Journal Select the user mode. See on Reset the fitness journal HOW to Reset the Fitness JournalExit the user mode HOW to USE the Stereo Sound System Optional Chest Pulse Sensor Information ModeHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Lower the Treadmill for USE Problem The power turns off during use TroubleshootingCompatible with GFCI-equipped outlets Problem The walking belt slows when walked on Problem Solution Exercise Intensity Exercise GuidelinesWorkout Guidelines Exercise FrequencySuggested Stretches Key No. Qty Description Part LIST-Model No. PFTL95908.0Key No. Qty Description Exploded Drawing A-Model No. PFTL95908.0 R0808A Exploded Drawing B-Model No. PFTL95908.0 R0808A Exploded Drawing C-Model No. PFTL95908.0 Exploded Drawing D-Model No. PFTL95908.0 R0808A Limited Warranty Ordering Replacement PartsIcon Health & Fitness, Inc., 1500 S W., Logan, UT