Weider 831.159730 Adjustment, Changing the Weight Setting, Adjusting the Leg Press Plate

Page 25

Adjustment

The instructions below describe how each part of the home gym can be adjusted. Refer to the exercise poster accompanying this manual to see how the home gym should be set up for each exercise. IMPORTANT: When using an attachment, make sure it is in the correct starting position for the exercise to be performed. If there is any slack in the cables or chain as an exercise is performed, the effectiveness of the exercise will be reduced.

Changing the Weight Setting

To change the setting of the weight stack, insert a Weight Pin (19) under the desired Weight (21). Make sure you insert the Weight Pin as far as it will go. Note: Due to the cables and pulleys, the amount of resistance at each exercise station may vary from the weight setting. Use the WEIGHT RESISTANCE CHART on page 27 to find the approximate amount of resistance at each weight station.

Attaching the Lat Bar, Nylon Strap or Ab Strap to the Low Pulley Station

Attach the Lat Bar (61) to the Low Pulley Cable (75) with a Cable Clip (69). For some exercises, the Chain (67) should be attached between the Lat Bar and the Low Pulley Cable with two Cable Clips. Adjust the length of the Chain between the Lat Bar and the Low Pulley Cable so the Lat Bar is in the correct starting position for the exercise to be performed.

The Nylon Strap (58) or Ab Strap (81) can be attached in the same manner.

Attaching the Lat Bar, Nylon Strap or Ab Strap to the High Pulley Station

Attach the Lat Bar (61) to the Press Cable (72) with a Cable Clip (69). For some exercises, the Chain (67) should be attached between the Lat Bar and the High Cable with two Cable Clips. Adjust the length of the

Chain between the Lat Bar and the High Cable so the Lat Bar is in the correct starting position for the exer- cise to be performed.

The Nylon Strap (58) or Ab Strap (81) can be attached in the same manner.

Adjusting the Leg Press Plate

To adjust the position of the Leg Press Plate (55), pull out the Lock Pin (91) and slide the Adjustment Tube (90) backwards or forwards in the bracket on the Leg Press Lever (83). Line up one of the adjustment holes in the Adjustment Tube with the hole in the bracket and re-insert the Lock Pin.

 

19

 

21

58

75

67

 

 

69

69

 

61

81

 

 

69

58

72

67

 

61

69

 

 

81

 

91

 

90

 

83

55

 

25

Image 25
Contents SEARS, Roebuck and CO. Hoffman ESTATES, IL Model No Serial NoImportant Precautions Table of ContentsBefore You Begin DimensionsFour Stages of the Assembly Process AssemblyLocknuts yet Frame AssemblyPage Locknuts yet Nylon Locknut the Leg Press Lever must pivot easily Nylon Locknuts yetGroove Pin Grooves Brackets Locate and open the parts bag labeled ARM Assembly Arm AssemblyLarge Cable Trap is oriented as shown Cable AssemblySmall Pulley Bracket is oriented exactly as shown Bracket is oriented as shown Pulley Plates are oriented as shownMake sure the Cable Trap is oriented as shown Page Cable Trap is oriented as shown Remove a Pro Pulley 26 from the bag labeled Pulley BAGRemove a Pro Pulley 26 from the bag labeled Pulley BAG Page Make sure the Cable Trap is oriented as shown Page Locate and open the parts bag labeled Seat Assembly Seat AssemblyLeg Press Plate must be on the upper edge Miscellaneous AssemblyWeider Cable Diagrams Press Cable Changing the Weight Setting AdjustmentAdjusting the Leg Press Plate Trouble-shooting and Maintenance High Arm Leg Butterfly Curl Ab Pulley Weight Resistance ChartPress Lbs Leg RaisePage R0800A Part Identification Chart-Model NoQty Description Part List-Model NoExploded Drawing-Model No Model No QUESTIONS?