AUTOMATIC UNBALANCE ADJUSTMENT
This system is to prevent abnormal vibration during intermittent spin and spin process.
FUNCTIONAL PRINCIPLE
1When the lid is closed, the safety switch
contact is “ON” position.
2In case that wash loads get uneven during spin, the outer tub hits the safety switch due to the serious vibration, and the spin process is interrupted.
3In case that P.C.B. ASS’Y gets “OFF” signal
from the safety switch, spin process are stopped and rinse process is started auto- matically by P.C.B. ASS’Y.
4If the safety switch is operated due to the unbalance of the tub, the program is stopped and the alarm is given.
Contact of safety switch Lid closing
Lid opening
| Contact lever A | |
Position of | Normal (ON) | |
unbalanced load (OFF) | ||
|
NOTES
The alarm finished when you close the lid after opening it. Check the unbalance of the wash load and the instal- lation condition.
CIRCULATING-WATER COURSE AND LINT FILTER
CIRCULATING-WATER
The washing and rinsing effects have been improved by adopting the water system in which water in the tub is circulated in a designed pattern.
When the pulsator rotates during the washing or rinsing process, the water below the pul- sator fans creates a water currents as shown in figure.
The water is then discharged from the upper part of the tub through the water channel. About 40 L/min. water is circulated at the ‘high’ water level, standard wash load and standard water currents.
Filter
Tub
| Filter | |
Water | Outer tub | |
channel | ||
| ||
Pulsator |
|
10FEATURE