8. PRESENTATION OF THE P.C.B ASS’Y
CONCERNING ERROR MESSAGE
| MESSAGE | CAUSE | SOLUTION | |
|
|
|
|
|
|
|
| Improper installation of drain hose. | Install drain hose properly. |
|
|
|
|
|
|
|
| The drain hose is blocked up by foreign | Remove foreign matter from drain hose. |
|
|
| ||
|
|
| matter. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Drain motor is inferior. | Change drain motor. |
|
|
|
|
|
|
|
| The water tap is closed. | Open the water tap. |
|
|
|
|
|
|
|
| The water inlet filter clogged. | Clean the water inlet filter. |
|
|
| ||
|
|
|
|
|
|
|
| It passes over the 60 minutes, yet it doesn’t | Check whether or not is comes to the |
|
|
| ||
|
|
| come to assigned water level. | assigned water level. |
|
|
|
|
|
|
|
| Wash loads get uneven during spin. | |
|
|
| ||
|
|
|
|
|
|
|
| Poor installation of the unit. | Proper installation. |
|
|
|
|
|
|
|
| The lid is opened. | Close the lid. |
|
|
| ||
|
|
|
|
|
|
|
| The safety switch is inferior. | Change the safety switch. |
|
|
|
|
|
|
|
| The load sensing is inferior. After the load |
|
|
|
| sensing operates about 7 seconds, the |
|
|
|
| message is displayed during 0.5 second | Change the P.C.B. ASS’Y. |
|
|
| and water level is always fixed ‘high’. |
|
|
|
|
| |
|
|
|
|
|
|
|
| The water level sensing is inferior. | Check the water level sensor and the |
|
|
| ||
|
|
|
| contact part of the connector. |
|
|
|
|
|
28PCB ASS’Y