Whirlpool 8562113 manual VentingRequirements, PlanVentSystem

Page 6

VentingRequirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ vent products are recommended.

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of this manual.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building.

Do not use an exhaust hood with a magnetic latch.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct. Do not use duct tape.

IMPORTANT: Observe all governing codes and ordinances.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Use a heavy metal vent. Do not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent crushing and kinking.

Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow.

An exhaust hood should cap the vent to prevent rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

PlanVentSystem

Typical installations vent the dryer from the rear of the dryer.

A

B

C

A. Exhaust hood

B. Flexible metal vent or rigid metal vent

C. Elbow

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions provided with the vent system.

AB

A. Over-The-Top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For ordering information see “Assistance or Service.”

Over-The-Top Installation: Part Number 4396028

Periscope Installation (for use with dryer vent to wall vent mismatch):

Part Number 4396037 - for mismatch of 0" (0 cm) to 18" (45.72 cm)

Part Number 4396011 - for mismatch of 18" (45.72 cm) to 29" (73.66 cm)

Part Number 4396014 - for mismatch of 29" (73.66 cm) to 50" (127 cm)

6

Image 6
Contents Volt Electric Compact Dryer 8562113Table DES Matières Dryer Safety Your safety and the safety of others are very importantInstallation Instructions ToolsandPartsLocationRequirements Mobile home installations require Recessed or closet installation Dryer onlyRecessed or closet installation Stacked Electrical RequirementsAlternate installations for close clearances VentingRequirementsPlanVentSystem Determine vent length Install VentSystemSpecial provisions for mobile home installations Flexible metalInstall cord bracket InstallCordBracketandCastersCompleteInstallation Install castersStoppingandRestarting Dryer USEStarting YourDryer To stop your dryerDrying,Cycle,andTemperatureTips LoadingCycles CleaningtheDryerInterior CleaningtheDryer LocationCleaningtheLintScreen Dryer CareTroubleshooting RemovingAccumulatedLintVacationandMovingCare Assistance or Service TheU.S.AInCanada Whirlpool Dryer Warranty Whirlpool Corporation will not pay forSécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteInstructions D’INSTALLATION Emplacementd’installationOutillageetpièces nécessaires Exigences concernant l’installation dans une maison mobile Dimensions de la sécheuseInstallation dans un encastrement ou placard Superposition Linstallation dans une maison mobile exigeExigencesconcernantlévacuation Instructions DE Liaison À LA TerreAutres installations où le dégagement est réduit Planification dusystèmedévacuationDétermination de la longueur du conduit Installation du conduitd’évacuation Installation dela brideducordonetdes roulettesInstaller les roulettes AcheverlinstallationInstaller la bride du cordon Conduitd’évacuationArrêtetremiseenmarche Utilisation DE LA SécheuseMiseen marchedelasécheuse Pour arrêter la sécheuseChargement ProgrammesNettoyagedelemplacementde Lasécheuse Nettoyagedu filtreàcharpieNettoyagedelintérieurdela sécheuse Dépannage Enleverla charpieaccumuléePrécautionsàprendrepourlesvacancesetavantun Déménagement Rétrécissement des articles Charpie sur la chargeTaches sur la charge ou décoloration Charges avec faux plisAssistance OU Service AuxÉtats-UnisAu Canada Garantie DE LA Sécheuse Whirlpool Whirlpool Corporation ne paiera pas pour8562113