Whirlpool 8562113 manual Install VentSystem, Special provisions for mobile home installations

Page 7

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent length

1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns when possible.

better good

2.Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

B

A

4"

(10.2 cm)

4" (10.2 cm)

A. Louvered style

B. Box hood style

The angled hood style (shown following) is acceptable.

4"

(10.2 cm)

2½" (6.4 cm)

See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and increased energy usage.

3.Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.

In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.

Vent Length Chart

Number of

Type of

Box or

Angled

90º turns

vent

louvered

hoods

or elbows

 

hoods

 

 

 

 

 

 

 

0

Rigid metal

36

ft (11 m)

26 ft (7.9 m)

 

Flexible metal

28

ft (8.5 m)

22

ft (6.7 m)

 

 

 

 

 

 

1

Rigid metal

26

ft (7.9 m)

16

ft (4.9 m)

 

Flexible metal

18

ft (5.5 m)

12

ft (3.7 m)

 

 

 

 

 

 

2

Rigid metal

16

ft (4.9 m)

6

ft (1.8 m)

 

Flexible metal

8

ft (2.8 m)

2

ft (0.6 m)

Install VentSystem

1.Before installing the vent system, be sure to remove the wire exhaust guard that is located at the exhaust outlet.

2.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

3.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

4.Run vent to dryer location. Use the straightest path possible. See “Determine vent length.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

7

Image 7
Contents 8562113 Volt Electric Compact DryerTable DES Matières Your safety and the safety of others are very important Dryer SafetyToolsandParts Installation InstructionsLocationRequirements Electrical Requirements Recessed or closet installation Dryer onlyRecessed or closet installation Stacked Mobile home installations requireVentingRequirements Alternate installations for close clearancesPlanVentSystem Flexible metal Install VentSystemSpecial provisions for mobile home installations Determine vent lengthInstall casters InstallCordBracketandCastersCompleteInstallation Install cord bracketTo stop your dryer Dryer USEStarting YourDryer StoppingandRestartingLoading Drying,Cycle,andTemperatureTipsCycles Dryer Care CleaningtheDryer LocationCleaningtheLintScreen CleaningtheDryerInteriorRemovingAccumulatedLint TroubleshootingVacationandMovingCare TheU.S.A Assistance or ServiceInCanada Whirlpool Corporation will not pay for Whirlpool Dryer WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheuseEmplacementd’installation Instructions D’INSTALLATIONOutillageetpièces nécessaires Linstallation dans une maison mobile exige Dimensions de la sécheuseInstallation dans un encastrement ou placard Superposition Exigences concernant l’installation dans une maison mobileInstructions DE Liaison À LA Terre ExigencesconcernantlévacuationPlanification dusystèmedévacuation Autres installations où le dégagement est réduitDétermination de la longueur du conduit Installation dela brideducordonetdes roulettes Installation du conduitd’évacuationConduitd’évacuation AcheverlinstallationInstaller la bride du cordon Installer les roulettesPour arrêter la sécheuse Utilisation DE LA SécheuseMiseen marchedelasécheuse ArrêtetremiseenmarcheProgrammes ChargementNettoyagedu filtreàcharpie Nettoyagedelemplacementde LasécheuseNettoyagedelintérieurdela sécheuse Enleverla charpieaccumulée DépannagePrécautionsàprendrepourlesvacancesetavantun Déménagement Charges avec faux plis Charpie sur la chargeTaches sur la charge ou décoloration Rétrécissement des articlesAuxÉtats-Unis Assistance OU ServiceAu Canada Whirlpool Corporation ne paiera pas pour Garantie DE LA Sécheuse Whirlpool8562113