Whirlpool 8316558 Power supply cord, Direct wire U.S. only, Grounding Instructions

Page 8
strain relief screws

7.U.S. installations:

Make electrical connection.

This dryer is manufactured with the cabinet-ground conductor connected to the NEUTRAL (center) of the wiring harness at the terminal block. If local codes do NOT permit this type of connection, use “Four- wire connection” instructions.

For a grounded, cord-connected appliance —

GROUNDING INSTRUCTIONS:

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

If using a power supply cord, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

For a permanently connected appliance —

GROUNDING INSTRUCTIONS:

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Canadian installations:

For a grounded, cord-connected appliance —

GROUNDING INSTRUCTIONS:

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Page 8

WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Power supply cord

(U.S. only)

Use a new UL-approved power supply cord rated 240-volt min., 30 amperes and marked for use with a clothes dryer.

WARNING

Fire Hazard

Use a new UL approved 30 ampere power supply cord.

Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

Direct wire (U.S. only)

WARNING

Fire Hazard

Use 10 gauge solid copper wire. Use a UL approved strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.Disconnect the power supply.

external ground conductor screw

tab hold-

terminal down

block screw cover

2.Remove hold-down screw and terminal block cover.

strain

dryer

relief

cabinet

clamp

 

sections

 

3. Assemble 3/4" U.L.-listed

strain relief (U.L. marking on strain relief) into the hole below terminal block opening. Tighten strain relief screws just enough to hold the two clamp sections together. Install power supply cord/cable through the strain relief.

Complete installation following instructions for your type of connection:

Four-wire (recommended method)

Three-wire (if four-wire is not available)

Image 8
Contents Installation Instructions Before you start It is your responsibility toTo change to a 30- or 60-minute timingcam Exhaust Hood TypeGas requirements Observe ALL Governing Codes and OrdinancesElectrical requirements Recommended ground methodNow Start Electrical requirements Grounding Instructions Power supply cordDirect wire U.S. only Four-wire connection Three-wire connection Direct Wire or Power Supply Cord Recessed area and closet installation instructions Product dimensions Bottom ExhaustInstructions d’installation Avant de commencer Votre sécurité et celle des autres est très importanteSpécifications du système d’évacuation Type DE Bouche DE DéchargeSécheuse à gaz SpécificationsInstallation électrique Méthode recommandée de liaison à la terreCommencer Sécheuse électrique Instructions DE Liaison À LA Terre Cordon d’alimentationCablâge direct Circuit à quatre conducteurs… Cordon D’ALIMENTATIONCircuit à trois conducteurs… Cordon D’ALIMENTATIONSi les codes locaux ne permettent pas Si vous avez besoin ’aide Instructions d’entretienDéménagement de la Sécheuse Dimensions du produit Évacuation PAR LE BAS