Alliance Laundry Systems FLW1525C manual Reinstallation of Shipping Materials

Page 23

Reinstallation of Shipping Materials

To prevent damage while moving the washer, the shipping materials MUST be reinstalled.

Disconnect washer from electrical supply.

While supporting the front access panel, remove two screws from the bottom edge of the panel.

Gently lower the panel to remove it from the washer.

Place the shock sleeves on all four shock absorbers. Refer to Figure 24.

Insert hooked end of shipping brace into the open slot of the motor mount. Refer to Figure 24.

Attach the brace with the five bolts and washers. Refer to Figure 24.

Reinstall front access panel.

1

 

 

 

 

2

 

 

3

 

4

FLW2124N

 

 

 

 

FLW2124N

1

Shock Sleeves

 

2

Motor Mount

 

3

Hooked End of Shipping Brace

4

Bolts and Lockwashers

 

Figure 24

Refer to Installation section, step 6 for proper procedures whenever the washer is moved.

Maintenance

Cleaning Foreign Object Trap

The washer’s pump has a trap that may collect foreign objects. The trap may need to be cleaned if water is draining slower than usual. To clean:

Disconnect washer from electrical supply.

While supporting the front access panel, remove two screws from the bottom edge of the panel.

Gently lower the panel to remove it from the washer.

NOTE: The pump may have some water in it. Use a rag or a container to catch water. If the wash drum is full of water, use a wet/dry shop vacuum to catch the water.

With rag or vacuum ready, unscrew the cap on the left side of the pump and remove trap.

Clean the debris from the trap.

Reinstall the trap and access panel.

Reconnect washer to electrical supply.

802951

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

21

Image 23
Contents Frontload Washers Page 802951 Contents Important Safety Instructions Safety InformationExplanation of Safety Messages Safety Information Dimensions and Specifications InstallationTools Before You StartPosition and Level the Washer Installing the WasherPosition Washer Near Installation Area Water Supply Connect Fill HosesImportant do not cross thread or overtighten couplings Connecting HosesRisers Standpipe Installation Wipe Out Inside of Wash Drum Remove the Shock Sleeves and Shipping BraceSupply Injection System Control Function TestElectrical Requirements Plug In the WasherGrounding Instructions Check InstallationClose Loading Door OperationOperation Instructions Load LaundrySet Fabric Selector Set Wash TemperatureAdd Laundry Supplies To Insert Money Set Soil LevelStart Washer Insert Coins or CardInsert COINS/CARD Indicator LightsUser-Maintenance Instructions MaintenanceCleaning Foreign Object Trap Reinstallation of Shipping MaterialsWasher Symptom Possible Cause/Solution TroubleshootingTroubleshooting Contact Information Page Installer Checklist