Alliance Laundry Systems HF150, HF234, HF304, HF185 instruction manual Operator Safety

Page 11

2

Operator Safety

WARNING

NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury.

To ensure the safety of machine operators, the following maintenance checks must be performed daily:

1.Prior to operating the machine, verify that all warning signs are present and legible. Missing or illegible signs must be replaced immediately. Make certain that spares are available.

2.Check door interlock before starting operation of the machine:

a.Attempt to start the machine with the door open. The machine should not start with the door open.

b.Close the door without locking it and attempt to start the machine. The machine should not start with the door unlocked.

c.Close and lock the door and start a cycle. Attempt to open the door while the cycle is in progress. The door should not open.

If the door lock and interlock are not functioning properly, call a service technician.

3.Do not attempt to operate the machine if any of the following conditions are present:

a.The door does not remain securely locked during the entire cycle.

b.Excessively high water level is evident.

c.Machine is not connected to a properly grounded circuit.

Do not bypass any safety devices in the machine.

WARNING

Never operate the machine with a bypassed or disconnected balance system. Operating the machine with severe out-of-balance loads could result in personal injury and serious equipment damage.

SAVE THESE INSTRUCTIONS

11

Image 11
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF150, IHF150, IHF033, CHF150, CHF033 Technical data and dimensionsDimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Surface Installation and Connection InstructionsOut of balance switch HF234-304 Removal of the transport safety665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical installationGrounding Instructions Connection label Main power connectionMachine Power Cable Connections Page Alternative Electric Heat Options Boiler Fed/Steam Heat Electric HeatLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF234 Annual maintenanceHF150 HF185Nameplate Location Contact InformationNameplate Replacement Parts Repair and after-sales service