Alliance Laundry Systems HF150, HF234, HF304 Dimensions HF185, IHF185, IHF045, CHF185, CHF045

Page 15

3

Dimensions HF185, IHF185, IHF045, CHF185, CHF045

Legend: metric mm [inches]

1376 [54.15]

1348 [53.07]

 

 

 

472 [18.58]

 

 

50 [1.97]

680 [26.77]

50 [1.97]

 

 

780 [30.71]

 

 

 

332 [13.05]

 

267 [10.49]

202 [7.93]

105 [4.13]

 

 

A

 

 

 

 

D

 

F

 

 

B

 

 

 

 

C

E

 

 

 

 

I

G

 

 

 

 

 

 

 

109 [4.3]

 

 

 

35 [1.38]

 

 

 

 

L

 

 

1141 [44.9]

1108 [43.6]

1066 [41.95]

 

1015 [39.96]

 

 

704 [27.7]

 

 

 

 

 

 

K

 

 

 

 

185 [7.29]

88 [3.47]

 

220 [8.66]

34 [1.34]

765 [30.12]

34 [1.34]

 

833 [32.8]

 

86.5 [3.41]

853 [33.58]

 

A. Ventilation soap dispenser

B. Liquid soap connections

C. Hard water connections 3/4"

D. Warm water connections 3/4"

E. Soft water connections 3/4"

F. Connection clamps

G. Electrical connections

I. Ventilation tub

K. Drain valve

L. Steam connections

170 [6.69]

15

Image 15
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF150, IHF150, IHF033, CHF150, CHF033 Technical data and dimensionsDimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Installation and Connection Instructions Out of balance switchSurface HF234-304 Removal of the transport safety665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical installationGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Alternative Electric Heat Options Boiler Fed/Steam Heat Electric HeatLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF234 Annual maintenanceHF150 HF185Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service