Water connection

The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably.

In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be available per unit. (See Table 1)

MODEL

Min Contents Boiler

METRIC

US

 

For the HF150, IHF150, IHF033, CHF150, CHF033

110 l.

3.88 ft³

For the HF185, IHF185, IHF045, CHF185, CHF045

130 l.

4.59 ft³

For the HF234, IHF234, IHF055, CHF234, CHF055

150 l.

5.30 ft³

For the HF304, IHF304, IHF075, CHF304, CHF075

180 l.

6.36 ft³

Table 1

MODEL

Inlet flow capacity per minute (Gallons / Liters)

INTERNATIONAL

US

 

For the HF150, 185

4.23 / 16

5.28 / 20

For the HF234, 304

7.93 + 13.2 / 30 + 50

7.93 + 13.2 / 30 + 50

Table 2

To comply with the WRAS water regulations: an 'approved' single check valve or some other no less effective backflow prevention device shall be fitted at the point of connection(s) between the supply and the fitting (IRN R150).

Water drain

The machine is equipped with a drain valve with 2" outer diameter (50 mm) for HF150- 185 and with 3" outer diameter (80 mm) for HF234-304. This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.

The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 80 l/min - 21.13 gal./min (HF150-

185) and 160 l/min - 42.26 gal./min (HF234-304) per machine.

It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation.

26

Image 26
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers Build-upSafety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HF150, IHF150, IHF033, CHF150, CHF033Dimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Surface Installation and Connection InstructionsOut of balance switch Removal of the transport safety HF234-304665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water connection Water drainElectrical installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Connection label Main power connectionMachine Power Cable Connections Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Liquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceHF185 Annual maintenanceHF150 HF234Nameplate Location Contact InformationNameplate Replacement Parts Repair and after-sales service