200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage):

With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power

wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.

200-240 volts, 1-Phase, 2-wire + PE, 50 Hertz (called 1-phase, 50 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 50Hz, after connecting the green/yellow PE ground wire, connect the power wire to the “L1” bottom terminal of the power contactor switch and the other wire, identified as the neutral wire, to the bottom terminal of the auxiliary contactor on the power contactor switch marked: “N”.

200-240 volts, 1-Phase, 2-wire + PE, 60 Hertz (called 1-phase, 60 Hz X-voltage):

With supply power of: 200-240 Volts, 1-phase, 2-wire, 60Hz, after connecting the green/yellow PE ground wire, connect one power wire to the “L1” and power wire to the “L2” of the bottom terminals of the power contactor switch.

After connection, check the spin direction. The cylinder must spin in the clockwise direction.

A wrong spin direction can damage the motor and can also cause water to spurt from the soap dispenser.

In case of wrong spin direction: switch the terminal clamps of the motor circuit “R” and “S” of the connecting cable or change the connection at the terminal block switching the L1 and L2 wires.

30

Image 30
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers Build-upSafety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HF150, IHF150, IHF033, CHF150, CHF033Dimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Installation and Connection Instructions Out of balance switchSurface Removal of the transport safety HF234-304665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water connection Water drainElectrical installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Liquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceHF185 Annual maintenanceHF150 HF234Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service