Alliance Laundry Systems HF185, HF234, HF304, HF150 instruction manual Liters / 75 pounds

Page 34

4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications HF304, IHF304, IHF075, CHF304, CHF075

304 liters / 75 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker (US- market)

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

 

NON-US

 

N

440-480

50/60

3

3+PE

16

20

20

12/4.0

 

42

50

 

50

8/10.0

P

380-415

50/60

3

3+N+PE

25

30

32

10/6.0

6x3 kW

51

60

 

60

6/16.0

Q

200-240

50/60

3

3+PE

25

30

32

10/6.0

71

80

 

80

4/25.0

 

 

X

200-240

50/60

1/3

2/3+PE

N/A

N/A

N/A

N/A

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

46

50

 

50

8/10.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x3 kW +

56

60

 

60

6/16.0

Q

200-240

50/60

3

3+PE

 

 

 

 

3x4 kW

N/A

N/A

 

N/A

N/A

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

51

60

 

60

6/16.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

6x4 kW

60

70

 

70

4/25.0

Q

200-240

50/60

3

3+PE

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

59

70

 

70

4/25.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x6 kW +

69

80

 

80

4/25.0

Q

200-240

50/60

3

3+PE

 

 

 

 

3x4 kW

N/A

N/A

 

N/A

N/A

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

Table 6

 

 

 

 

 

 

 

34

Image 34
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers Build-upSafety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HF150, IHF150, IHF033, CHF150, CHF033Dimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Out of balance switch Installation and Connection InstructionsSurface Removal of the transport safety HF234-304665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water connection Water drainElectrical installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Machine Power Cable Connections Main power connectionConnection label Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Liquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceHF185 Annual maintenanceHF150 HF234Nameplate Contact InformationNameplate Location Replacement Parts Repair and after-sales service