Alliance Laundry Systems HF150 Technical remarks, Internal connections of the electrical heating

Page 39

Technical remarks

 

 

 

 

 

 

6

Internal connections of the electrical heating

 

 

 

 

1 AC

 

 

 

 

 

 

 

Heating

 

R5

 

 

 

 

 

3kw

 

LC1D0901

 

 

 

 

 

 

Table 8

 

 

 

 

3 AC

 

 

 

 

 

 

 

Heating

 

 

3x230V

R5

3x400V

R5

 

 

 

 

4,2kw

 

3x1,4kw

See Label 15

LC1D0901

See Label 16

LC1D0901

 

6kw

 

3x2kw

See Label 15

LC1D0901

See Label 16

LC1D0901

 

9kw

 

3x3kw

See Label 15

LC1D1810

See Label 16

LC1D0901

 

12kw

 

3x4kw

--------

--------

See Label 15

LC1D0901

 

12kw

 

3x2kw

See Label 15

LC1D1810

See Label 16

LC1D1810

 

 

 

3x2kw

See Label 15

LC1D1810

 

 

 

15kw

 

3x2kw

See Label 15

LC1D1810

See Label 16

LC1D1810

 

 

 

3x3kw

See Label 15

LC1D1810

 

 

 

18kw

 

3x3kw

See Label 15

LC1D1810

See Label 16

LC1D1810

 

 

 

3x3kw

See Label 15

LC1D1810

 

 

 

21kw

 

3x3kw

--------

--------

See Label 16

LC1D1810

 

 

 

3x4kw

 

 

See Label 15

LC1D1810

 

24kw

 

3x4kw

--------

--------

See Label 15

LC1D1810

 

 

 

3x4kw

 

 

See Label 15

LC1D1810

Table 9

B = Black

Br = Brown

Gy = Grey

Bu = Blue

R = Red

W = White

 

 

 

 

 

 

Label 16

 

Label 15

"Delta" configuration

"WYE" configuration

NOTE:

Other executions are available as options.

39

Image 39
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF150, IHF150, IHF033, CHF150, CHF033 Technical data and dimensionsDimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Installation and Connection Instructions Out of balance switchSurface HF234-304 Removal of the transport safety665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical installationGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Alternative Electric Heat Options Boiler Fed/Steam Heat Electric HeatLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF234 Annual maintenanceHF150 HF185Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service