Alliance Laundry Systems HF304 instruction manual Annual maintenance, HF150, HF185, HF234

Page 41

7

Annual maintenance

Belt tension:

Verify that the belts are running in the middle of the basket pulley.

Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).

Belt tension testing table

Model

 

Belt

Frequency (Hz)

Tension force (N)

Deflection (mm)

Deflection force

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at MIN

at MAX

 

 

 

 

MIN

MAX

MIN

MAX

tension

tension

MAX

HF150

10J

1549

91

111

708

1050

7,3

5,3

50

HF185

10J

1549

91

111

708

1050

7,3

5,3

50

HF234

10J

1663

87

92

821

1050

7,4

6,6

50

HF304

10PK 2120

62

67

1067

1182

10,6

5,6

75

1 Deflection

2 Span length

41

Image 41
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Build-up Model NumbersSafety Safety and Environmental InformationsDisposal of Unit EnvironmentalExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data HF150, IHF150, IHF033, CHF150, CHF033 Technical data and dimensionsDimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Surface Installation and Connection InstructionsOut of balance switch HF234-304 Removal of the transport safety665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water drain Water connectionImportant Do not use fuses in place of a circuit breaker Electrical installationGrounding Instructions Connection label Main power connectionMachine Power Cable Connections Page Alternative Electric Heat Options Boiler Fed/Steam Heat Electric HeatLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Connection of the liquid soap hoses Liquid soap connection optionWith an external tension 24V DC See Label Label With direct steam injection into the machine See Table Steam connectionInternal connections of the electrical heating Technical remarksEnd of day General maintenance Periodical maintenance Maintenance instruction of the machineHF150 Annual maintenanceHF185 HF234Nameplate Location Contact InformationNameplate Replacement Parts Repair and after-sales service