Technical data HF304, IHF304, IHF075, CHF304, CHF075

 

METRIC

US

Capacity (dry weight) Ratio [kg/Lit]

 

 

1:11

27,6 kg

60.85 lb.

1:10

30,4 kg

67.02 lb.

1:9

33,7 kg

74.30 lb.

Cylinder

 

 

Diameter

850 mm

33.46 inch

Depth

537 mm

21.14 inch

Volume

304 Lit

10.74 ft³

Cabinet

 

 

Height

1558 mm

61.32 inch

Width

1060 mm

41.73 inch

Depth

1147 mm

45.16 inch

Front loading

 

 

Diameter door opening

400 mm

15.75 inch

Height under door

567 mm

22.32 inch

To center

845 mm

33.27 inch

Speed

 

 

Wash

10 - 50 tr/min - RPM

Distribution

 

85 tr/min - RPM

Spin

250 - 1000 tr/min - RPM

G-factor

 

 

High spin

 

475

Dynamic bottom load (N/Hz)

 

 

 

 

2340/16

Motor (3-phase)

 

 

4p. 1470 tr/min

 

4 kW / 5,36 HP

Drain valve

 

 

 

 

3"

Water supply

 

 

Hard, soft, warm water

 

3/4"

Steam connection

 

 

Steam connection

 

1/2"

Heating

 

 

Electrical 230/400 V

 

18 kW

Electrical 400V

 

21 kW - 24 kW

Steam

 

6 bar

Warm water (without additional heating)

X

Warm water (with additional heating)

X

Packing dimensions

 

 

(H x W x D) mm - inch

1740x1120x1260 mm - 68.50x44.09x49.61inch

Weight

 

 

Net

731 kg

1611.58 lb.

Gross

781 kg

1721.81 lb.

18

Image 18
Contents Washer Extractors Page Contents Internal connections of the electrical heating  Model Numbers Build-upSafety and Environmental Informations SafetyEnvironmental Disposal of UnitExplanation of Safety Messages Important Safety Instructions Page Operator Safety Technical data and dimensions Technical data HF150, IHF150, IHF033, CHF150, CHF033Dimensions HF150, IHF150, IHF033, CHF150, CHF033 Technical data HF185, IHF185, IHF045, CHF185, CHF045 Dimensions HF185, IHF185, IHF045, CHF185, CHF045 Technical data HF234, IHF234, IHF055, CHF234, CHF055 Dimensions HF234, IHF234, IHF055, CHF234, CHF055 Technical data HF304, IHF304, IHF075, CHF304, CHF075 Dimensions HF304, IHF304, IHF075, CHF304, CHF075 Installation and Connection Instructions Out of balance switchSurface Removal of the transport safety HF234-304665 733 680 780 765 833 680 780 830 900 738 960 1040 97.5 865 1060 Water connection Water drainElectrical installation Important Do not use fuses in place of a circuit breakerGrounding Instructions Main power connection Machine Power Cable ConnectionsConnection label Page Boiler Fed/Steam Heat Electric Heat Alternative Electric Heat OptionsLiters / 45 pounds Liters / 55 pounds Liters / 75 pounds Liquid soap connection option Connection of the liquid soap hosesWith an external tension 24V DC See Label Label Steam connection With direct steam injection into the machine See TableTechnical remarks Internal connections of the electrical heatingMaintenance instruction of the machine End of day General maintenance Periodical maintenanceHF185 Annual maintenanceHF150 HF234Contact Information NameplateNameplate Location Replacement Parts Repair and after-sales service