8. TROUBLESHOOTING
8-1.BEFORE PERFORMING SERVICE
Be careful of electric shock or disconnecting the parts while troubleshooting.
Voltage of each terminal in AC
8-2.QC TEST MODE.
Pressing RINSE ( ), and SPIN ( ) button simultaneously.
Power supply ON with pressing upper two button. then buzzer sound twice.
Press the START/PAUSE ( |
|
|
|
|
|
| ) button as follows. |
|
| ||||||
|
| ||||||
Press the START/PAUSE ( |
|
|
|
|
|
| ) button more 4 times until stop spinning |
|
|
|
|
|
■
Pressing number of | Checking Point | Display Status | |||
START/PAUSE | button | ||||
|
| ||||
None |
|
| All lamps turn on |
| |
|
|
|
|
| |
1 time |
|
| Clockwise spin (right) | Motor rpm (About 45) | |
|
|
|
|
| |
2 times |
|
| Low speed spin | Motor rpm (About 63~67) | |
|
|
|
|
| |
3 times |
|
| High speed spin | Motor rpm (About 114~117) | |
|
|
|
|
| |
4 times |
|
| Inlet valve for | Water level frequency (25~65) | |
|
|
|
|
| |
5 times |
|
| Inlet valve for | Water level frequency (25~65) | |
|
|
| |||
|
| Hot inlet valve in case of hot water fill | |||
|
|
|
| ||
|
|
|
|
| |
6 times |
|
| Inlet valve for | Water level frequency (25~65) | |
|
|
|
|
| |
7 times |
|
| Counterclockwise spin (left) | Motor rpm (About 45) | |
|
|
|
|
| |
8 times |
|
| A Heater is in operation for 3 sec. | Water Temperature | |
|
|
|
|
| |
9 times |
|
| Draining pump operation | Water level frequency | |
|
|
|
|
| |
10 times |
|
| Auto off operation |
| |
|
|
|
|
|
20