HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
■
(1) |
When disconnect the connector(1) on the |
| |
PWB assembly (Main) is the resistance of the |
| |
natural connectors | ( Blue/White, Violet), |
|
(Blue, White) | between 2.5k to 180k |
|
(105 ~0 )? | 2 | 1 |
| ||
| 4 | 3 |
YES
When checking thermistor on the tub cover, is the thermistor loosened above 2mm from the rubber?
NO
YES
Replace the thermistor. (6322FR2046B)
Press the thermistor tightly to the rubber.
■WD-803(4)0(W)(F)(H)/WD-102(4)1(5)W(F)(H)/WD-1042F(H)
1
Is the resistance between two receptacles with |
| ||
BL/WH wires parted from PWB assembly | NO | ||
2.5k | to 180k (105 ~0 )? | ||
|
YES
When checking thermistor on the tub cover,
is the thermistor gotten more than 2 mm out of the | YES |
| |
rubber? |
|
Replace the thermistor. (6322FR2046B)
Get the thermistor back to the rubber.
36