Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.
NOTE: The reactor coil is wired in series with line 1 internally in the Control Board. An open coil or loose electrical connection would result in a “dead” board complaint. A resistance check across the coil leads should indicate less than 1 ohm.
EMI Filter Removal
1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Loosen 13mm acorn nut and slide EMI Filter out of bracket.
Reactor Removal
1.Disconnect power supply to unit.
2.Remove Top Cover.
3.Remove single attachment screw on cross brace.
4.Twist Reactor counterclockwise to remove.
NOTE: Mark the wire locations on the EMI before removing the terminals.