Troubleshooting Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.
Diag. | Description | Trigger | Action to be | |
Code |
|
| taken | |
|
| Input signal |
| |
|
| from water |
| |
|
| level Sensor | Displays "LE" | |
| Water level | is out of | ||
8 | range, | Go to “No water fill | ||
sensor fault. | ||||
| Washer will | Troubleshooting”. | ||
|
| |||
|
| beep and |
| |
|
| pause the |
| |
|
| wash cycle. |
| |
9 |
| Not Used | ||
|
|
|
| |
| Unbalance |
|
| |
| detected | Never | LED – Will display | |
| during final | |||
| exceeded | |||
| spin, which | “dc” | ||
10 | 400rpm due | |||
prevented | to an | Go to "Wet Clothes | ||
| the spinner | "Troubleshooting | ||
| unbalance | |||
| from | Section" | ||
| load. | |||
| exceeding |
| ||
|
|
| ||
| 400 rpm |
|
| |
|
| Water level in |
| |
|
| the machine |
| |
|
| is believed to |
| |
|
| be above the |
| |
|
| overflow level. |
| |
|
| When this |
| |
|
| condition is | First check to see | |
| Water | detected, the | that water valve is | |
E | sensor level | machine will | not stuck. If water | |
| fault. | automatically | valve is OK, check | |
|
| begin | water level sensor | |
|
| pumping |
| |
|
| water out of |
| |
|
| the machine |
| |
|
| until it falls |
| |
|
| below the |
| |
|
| overflow level. |
| |
|
|
| Go to "Clear | |
|
|
| diagnostic codes" | |
|
|
| Disconnect and | |
| Will not | Difficulty in | reconnect the | |
| washer power cord | |||
| remember | |||
11 | reading | at power supply | ||
machine | ||||
| memory | outlet. | ||
| settings | |||
|
| If condition still | ||
|
|
| ||
|
|
| exists, replace | |
|
|
| machine control | |
|
|
| board. |
Diag. | Description | Trigger | Action to be | |
Code |
|
| taken | |
|
| A key is | Display "E2". Go to | |
|
| sensed to be | "Membrane Pad | |
|
| pressed more | Check" Check | |
15 | Stuck Key | than 30 | connection of | |
seconds, the | keypad to control | |||
|
| |||
|
| key will be | board. Replace | |
|
| assumed to | LED Board if | |
|
| be stuck | necessary. | |
|
| The door has |
| |
|
| not been |
| |
| Door switch | opened after |
| |
| was not | two complete | Will display "od" If | |
17 | seen open | wash cycles. | door open sensing, | |
| since the last | Door switch | will cleared. | |
| three final | was not seen | ||
|
| |||
| spins | open since |
| |
|
| the last two |
| |
|
| final spins |
| |
|
|
| Check for loose | |
|
|
| wire connections | |
|
|
| Clear the diagnostic | |
| Detected |
| code and recheck; | |
| door lock | Open door | if reoccurs, perform | |
18 | switch open | lock switch | Diagnostic | |
during cycle | with motor | Motor/Machine | ||
| ||||
| when not | running. | Control Board test | |
| expected. |
| Check for faulty | |
|
|
| motor relay on the | |
|
|
| machine control | |
|
|
| board. | |
| Not Used | |||
|
|
|
| |
| Door switch | Door switch is | Go to "Door Lock | |
| detected open | |||
| detected | and the door | Test" | |
22 | open during | |||
| cycle (when | locked switch | Troubleshooting | |
| not paused). | is read as | Section | |
| locked. |
| ||
|
|
| ||
| Not Used | |||
|
|
|
|
Not Used
©2005 Maytag Services | 16025909 Rev. 0 | 19 |