3.Remove existing label from the opposite side of the door and discard. Find label provided with the Use and Care Guide and apply over original hinge holes.
4.Align the door by placing the locating tabs on the hinge with the locating holes on the dryer front panel. Insert and tighten the center hinge screw. The door will hang in place while you insert and tighten the remaining 4 screws.
NOTE: Two or more people may be needed to reattach the dryer door.
A
B
C
A. Dryer door
B. Dryer front panel
C. Insert this hinge screw first.
5.Close the door and check that it latches securely.
6.Check for fingerprints on the glass. Clean the glass if necessary.
Complete Installation
1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2.Check that you have all of your tools.
3.Check the dryer’s final location. Be sure the vent is not crushed or kinked.
4.Check that the dryer is level. See “Level Dryer.”
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
5.Plug into a grounded 3 prong outlet. Turn on power.
6.Remove any protective film or tape remaining on the dryer.
7.Dispose of/recycle all packaging materials.
8.Read “Dryer Use.”
9.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
10.Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only Temperature setting.
If the dryer will not start, check the following:
■Dryer is plugged into a grounded 3 prong outlet.
■Electrical supply is connected.
■Household fuse is intact and tight, or circuit breaker has not tripped.
■Dryer door is closed.
11.When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check that the gas supply line shutoff valve is open.
■If the gas supply line shutoff valve is closed, open it, then repeat the
■If the gas supply line shutoff valve is open, contact a qualified technician.
15