Kenmore 110.9787 manual Gas Supply Requirements

Page 8

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use LP gas, ³⁄₈" LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.

NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape.

Must include a shutoff valve:

An individual shutoff valve must be installed within 6 feet

(1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.

A C E

BD

A. ³⁄₈" flexible gas connector

B. ³⁄₈" pipe to flare adapter fitting

C. ¹⁄₈" NPT minimum plugged tapping

D. ½" NPT gas supply line

E. Gas shutoff valve

Gas Type

Natural gas:

This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Your dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your local Sears store or Sears Service Center.

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.

Gas supply line

Must include ¹⁄₈" NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration).

¹⁄₂" IPS pipe is recommended.

³⁄₈" approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit.

If you are using Natural gas, do not use copper tubing.

Gas supply connection requirements

Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON®† tape.

This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24.

Burner input requirements

Elevations up to 10,000 ft (3,048 m):

The design of this dryer is certified by CSA International for use at altitudes up to 10,000 ft (3,048 m) above sea level at the Btu rating indicated on the model/serial number plate.

Burner input adjustments are not required when the dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

8

Image 8
Contents Gas Dryer Table of Contents Kenmore Elite Appliance WarrantyDryer Safety Product RecordParts supplied Installation InstructionsTools and Parts Optional Pedestal Location RequirementsDryer Dimensions Installation spacing for cabinet installationCloset installation Dryer only Recessed or closet installation Dryer on pedestalElectrical Requirements Mobile home additional installation requirementsMobile home installations require Gas Supply Requirements If using an existing vent system Venting RequirementsDryer gas pipe If this is a new vent system Vent materialOptional exhaust installations Plan Vent SystemClamps ExhaustAlternate installations for close clearances Special provisions for mobile home installationsVent system chart Determine vent pathInstall Vent System Install Leveling LegsLevel Dryer Make Gas ConnectionRemove the door Reverse Door SwingConnect Vent Reverse the door handle Reinstalling the doorReverse the hinge Complete Installation If the dryer will not start, check the followingDryer USE Starting Your DryerTo use an Auto Cycle To make changes during an Auto CyclePausing or Restarting Stopping Your DryerControl Locked Drying and Cycle TipsStatus Lights CyclesAuto Dry Preset Cycle Settings Timed Preset Cycle SettingsTimed Cycles Timed DryOptions End of Cycle Signal Changing the Preset Dryness Level SettingsEnd of Cycle Signal Tumble Free Heated Dryer RackCleaning the Dryer Location Cleaning the Lint ScreenCleaning the Dryer Interior Dryer CareTroubleshooting Vacation and Moving CareChanging the Drum Light Dryer OperationDryer Results Master Protection Agreements Sears Installation ServiceProtection Agreements Índice USO DE LA SecadoraGarantía DE LOS Electrodomésticos Kenmore Elite Garantía Limitada DE UN AÑOSeguridad DE LA Secadora Su seguridad y la seguridad de los demás es muy importanteInstrucciones DE Instalación Herramientas y piezasPiezas suministradas Piezas para adquirirRequisitos de ubicación Pedestal opcionalUsted necesitará 4663Dimensiones de la secadora Espacios para la instalaciónEspacio para la instalación en el gabinete Instalación en el clóset Sólo secadoraRequisitos eléctricos Las instalaciones en casas rodantes necesitanRequisitos del suministro de gas Requisitos de ventilación El tubo de gas de la secadoraSi usa un sistema de ventilación existente Si éste es un nuevo sistema de ventilaciónInstalaciones opcionales de escape RespiraderoInstalación del sistema de ventilación Instalaciones alternas para espacios limitadosDeterminación de la vía del ducto de escape Cuadro del sistema de ventilaciónInstalación de las patas niveladoras Nivelación de la secadoraConexión del suministro de gas Para su uso en casas rodantesConexión del ducto de escape Inversión del cierre de la puertaDesmontaje de la puerta Inversión de la bisagraInversión de la manija de la puerta Reinstalación de la puertaComplete la instalación Si la secadora no funciona, revise lo siguientePara usar un ciclo de secado automático USO DE LA SecadoraPuesta en marcha de la secadora Detención de la marcha De la secadora Pausa o reanudación de la marchaControl bloqueado Sugerencias de ciclos y secadoLuces de estado CiclosPantalones de mezclilla Jeans Informal CasualRopa delicada Delicate Ajustes de ciclos prefijados de secado automáticoSeñal de secado húmedo Damp Dry Signal OpcionesAjustes de ciclos prefijados manuales Sonidos de los botones Button SoundsModificadores Cambio de ciclos, opciones y ModificadoresEstante térmico de la secadora Señal de fin de ciclo End of Cycle SignalSeñal de fin de ciclo Cuidado DE LA Secadora Limpieza del lugar donde está La secadoraLimpieza del filtro de pelusa Limpieza del interior de la secadoraSolución DE Problemas Eliminación de pelusa acumuladaCambio de la luz del tambor Funcionamiento de la secadoraEl tiempo del ciclo es demasiado corto Resultados de la secadoraLa secadora muestra mensajes codificados Contratos DE Protección W10114658