ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint. When adding ducts, the ducts to be added should overlap the duct to which it is con- nected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the building. Additionally, inspection doors should be installed at strategic points in the exhaust duct work for periodic inspection and clean-out of lint from the duct work.

To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downward should be installed where the exhaust exits the building. If the duct work travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction (i.e., roof or ground level).

IMPORTANT: Exhaust back pressure measured by a manometer at the dryer exhaust duct area must not exceed 0.3 inches of water column.

NOTE:Where the exhaust duct work passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches larger (all the way around) than the duct. The duct must be centered within this opening.

a. Outside Duct Work Protection

1)To protect the outside end of horizontal duck work from the weather, a 90° elbow bent downward should be installed where the exhaust exits the building. If the exhaust duct work travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction.

IMPORTANT: DO NOT use screens or caps on the outside of opening of exhaust duct work.

15

Image 19
Contents AD-120ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications Specifications / Component IdentificationADG-120ES ADE-120ES ADS-120ES Dryer Front View Component IdentificationDryer Rear View Location Requirements Installation ProceduresUNPACKING/SETTING UP Leveling Dryer Dryer Enclosure Requirements Fresh AIR Supply General Exhaust Duct Work Information Exhaust RequirementsPage Single Dryer Venting Multiple Dryer Common Venting Page ADG-120ES for GAS Models ADE-120ES for 80 KW Electric Models Page Electrical Information ADG-120ES Reversing, 3ø GAS ADS-120ES Reversing, 3ø Steam Electrical Service Specifications PER DryerADE-120ES 72 Kw Electric Reversing, 3ø ADE-120ES 80 Kw Electric Reversing, 3ø Page Page Gas Supply GAS InformationType of Gas Page Page Steam Coil PH Level Installation InstructionsSteam Requirements , High Pressure Steam Damper System Steam Damper System Operation Steam Damper AIR System ConnectionsSteam Damper AIR Piston Flow Control Operation Adjustment Preparation for Operation Natural GAS Preoperational TestsPage Page Operating Instructions Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceDays Lubrication AdjustmentsNo L.E.D. display microprocessor computer models only TroubleshootingDrive motor not operating does not start Blower motor not operating does not start Microprocessor controller computer display reads door Microprocessor computer display reads dSFLPage No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise and/or vibration Dryer or scraping noise at basket tumbler areaDrive motor only not operating does not start Failed reversing timer for Reversing Models onlyBlower impellor/fan motor only not operating does not start Dryer operates but is taking too long to dry load Heat unit not operating for only one 1 temperature selectionFailed hi-limit thermostat for GAS and Electric Models only Sail switch is fluttering for GAS and Electric Models onlyDryer scraping noise at basket tumbler area Timing Legend Reversing Timer SPIN/DWELL AdjustmentsMicroprocessor computer Board Procedure for Functional Check Replacement ComponentsDirect Spark Ignition DSI System