American Dryer AD-120ES manual

Page 41

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

b.Electric Models

1)Check the oven contactor(s) to insure that the electric oven is cycling properly.

c.Steam Models

1)Check to insure that steam damper is functioning properly.

a)The steam damper should not "slam" (open or closed) when it reaches the end of (piston) travel. Additionally, the steam damper should not bind and/or stop during travel. If either of these conditions occur, the flow control must be adjusted. Refer to the bottom illustration on page 35 for air adjustment instructions.

6.Make a complete operational check of ALL safety-related circuits (i.e., lint drawer switch, and sail switch on gas models).

NOTE: To check for proper sail switch operation, open the main door and while holding main door switch plunger in, start dryer. Dryer should start but heat circuit should not be activated (on). If heat (burner) does activate, shut dryer off and make necessary adjustments.

7.A reversing basket (tumbler) dryer should never be operated with less than a 60 lb. load (dry weight). The size of the load will affect the coast-down and dwell (stop) times. The basket (tumbler) must come to a complete stop before starting in opposite direction.

a.Microprocessor (computer) Dryer Models

1)Spin and stop times are not adjustable in the Automatic Mode and have been preprogrammed into the microprocessor controller (computer) for 120-seconds spin time and a 5-second dwell (stop) time.

2)Spin and stop times are adjustable in the Manual (timed) Mode.

b.Dual Timer Dryer Models

1)Spin and stop times are adjustable at the reversing timer (refer to page 58).

IMPORTANT: The dryer basket (tumbler) is treated with a protective coating ADC suggests tumbling old clothes or material in the basket (tumbler), using a mild detergent to remove the protective coating.

37

Image 41
Contents AD-120ES Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsStandards Specifications Specifications / Component IdentificationADG-120ES ADE-120ES ADS-120ES Dryer Front View Component IdentificationDryer Rear View Location Requirements Installation ProceduresUNPACKING/SETTING UP Leveling Dryer Dryer Enclosure Requirements Fresh AIR Supply General Exhaust Duct Work Information Exhaust RequirementsPage Single Dryer Venting Multiple Dryer Common Venting Page ADG-120ES for GAS Models ADE-120ES for 80 KW Electric Models Page Electrical Information ADG-120ES Reversing, 3ø GAS ADS-120ES Reversing, 3ø Steam Electrical Service Specifications PER DryerADE-120ES 72 Kw Electric Reversing, 3ø ADE-120ES 80 Kw Electric Reversing, 3ø Page Page Gas Supply GAS InformationType of Gas Page Page Steam Requirements , High Pressure Installation InstructionsSteam Coil PH Level Steam Damper System Steam Damper System Operation Steam Damper AIR System ConnectionsSteam Damper AIR Piston Flow Control Operation Adjustment Preparation for Operation Natural GAS Preoperational TestsPage Page Operating Instructions Shut Down Instructions Parts SERVICE/PARTS InformationService Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceDays Lubrication AdjustmentsDrive motor not operating does not start TroubleshootingNo L.E.D. display microprocessor computer models only Blower motor not operating does not start Microprocessor controller computer display reads door Microprocessor computer display reads dSFLPage No heat for Electric Models only No heat for Steam Models onlyCondensation on main door glass Dryer operates but is taking too long to dryExcessive noise and/or vibration Dryer or scraping noise at basket tumbler areaBlower impellor/fan motor only not operating does not start Failed reversing timer for Reversing Models onlyDrive motor only not operating does not start Dryer operates but is taking too long to dry load Heat unit not operating for only one 1 temperature selectionFailed hi-limit thermostat for GAS and Electric Models only Sail switch is fluttering for GAS and Electric Models onlyDryer scraping noise at basket tumbler area Timing Legend Reversing Timer SPIN/DWELL AdjustmentsMicroprocessor computer Board Procedure for Functional Check Replacement ComponentsDirect Spark Ignition DSI System