American Dryer ML-200 manual Type of GAS

Page 26

2.Technical Gas Data a. Gas Specifications

 

 

 

TYPE OF GAS

 

 

 

 

 

 

 

 

Natural

 

Liquid Propane

 

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

 

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

 

Inline Pressure

6.0 - 12.0 inches W.C.

 

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at gas valve pressure tap when the gas valve is on.

b.Gas Connections:

Inlet connection ---- 1-1/4 inch N.P.T. Inlet Supply Size ---- 1-1/2 inch N.P.T.

Btu/hr input --------- 750,000 (189,000 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryers gas valve internal regulator. Incoming supply pressure must be consistently between a minimum of 6.0 (14.92 mb) and a maximum of 12.0 inches water column (29.9 mb) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with liquid propane (L.P.) gas have both of their gas valve's internal pressure regulators blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure is measured at each gas valve pressure tap must be a consistent 10.5 inches water column (W.C.) - 26.1 mb. There is no regulator or regulation provided in an L.P. gas dryer. The water column must be regulated at the source (L.P. tank) or external regulator/regulation must be added to each dryer.

 

 

 

 

 

 

TYPE OF GAS

 

L.P.

 

 

 

 

 

 

 

 

 

 

Conversion Kit

 

BTU

 

 

Natural

 

 

Liquid Propane

MODEL

kcal/hr

 

 

 

Part

Per Hour

 

 

 

 

 

 

 

NUMBER

Rating

Qty.

D.M.S.*

 

Part

Qty.

D.M.S.*

Part

Number

Rating

 

Number

Number

 

 

 

 

 

 

 

 

MLG-200**

750,000

189,000

5

#1

 

140840

5

#28

140821

880754

 

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

*D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas

#1 =

.2280" (5.7912 mm)

Liquid Propane

#28 =

.1405" (3.5687 mm)

22

Image 26
Contents ML-200 Non-Tilting Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage Specifications GAS and Steam Models Component IdentificationML-200 Dimensions and Component Location Page Installation Procedures Reassembly of DryerPage Page Location Requirements Fresh AIR Supply Exhaust Requirements Page Compressed AIR Supply System Electrical Information Electrical RequirementsMLG-200 Gas Hp Blower/3 Hp Drive Motor MLS-200 Steam Hp Blower/3 Hp Drive Motor Page GAS Information Type of GAS Latest Edition Page Steam Information System Connections Section H, itemPage Compressed Air Supply Air Pressure Diagram Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions Parts SERVICE/PARTS InformationService Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers only Adjustments LubricationTUMBLER/BASKET Component System DescriptionsTumbler Basket Drive System AIR Blower Drive SystemSafety Devices Load Door SwitchesSteam Damper Actuator System Troubleshooting No DisplayFailed reversing contactor relay Failed microprocessor controller computer Page Blown 24 VAC control circuit fuse fuse Page For GAS Models only Excessive noise and/or vibration Tumbler basket out of alignment Procedure for Functional Check Replacement Components Page Page Manual Reset HI-LIMIT Instructions P O R T a N TADC113142 1- 04/21/00-8