American Dryer ML-200 manual Compressed Air Supply Air Pressure

Page 31

4.Steam Damper Air System Connections

The ML-200 is manufactured with a pneumatic (piston) damper system which requires an external supply of compressed air. The air connection is made to the steam damper solenoid valve which is located on the outer top, at the rear left hand corner of the dryer.

a. Air Requirements

Compressed Air Supply

 

Air Pressure

 

 

 

 

Normal

 

80 PSI

5.51 bars

 

 

 

 

Minimum Supply

 

70 PSI

4.82 bars

 

 

 

 

Maximum Supply

 

90 PSI

6.20 bars

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

b.Air Connection

Air connection to system --- 1/8-inch F.P.T.

c.No air regulation is provided with the dryer. External regulation of 80 PSI (5.51 bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

5.Steam Damper System Operation

The MLS-200 steam damper, as shown in Diagram 1 on page 28, allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn directly into the tumbler (basket), allowing a rapid cool down.

27

Image 31
Contents ML-200 Non-Tilting Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Component Identification Specifications GAS and Steam ModelsML-200 Dimensions and Component Location Page Reassembly of Dryer Installation ProceduresPage Page Location Requirements Fresh AIR Supply Exhaust Requirements Page Compressed AIR Supply System Electrical Requirements Electrical InformationMLG-200 Gas Hp Blower/3 Hp Drive Motor MLS-200 Steam Hp Blower/3 Hp Drive Motor Page GAS Information Type of GAS Latest Edition Page System Connections Section H, item Steam InformationPage Compressed Air Supply Air Pressure Diagram Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Parts Warranty InformationReturning Warranty Cards WarrantyPage Cleaning Routine MaintenanceSteam Dryers only Lubrication AdjustmentsAIR Blower Drive System Component System DescriptionsTumbler Basket Drive System TUMBLER/BASKETLoad Door Switches Safety DevicesSteam Damper Actuator System No Display TroubleshootingFailed reversing contactor relay Failed microprocessor controller computer Page Blown 24 VAC control circuit fuse fuse Page For GAS Models only Excessive noise and/or vibration Tumbler basket out of alignment Procedure for Functional Check Replacement Components Page Page P O R T a N T Manual Reset HI-LIMIT InstructionsADC113142 1- 04/21/00-8