American Dryer ML-200 manual Location Requirements

Page 16

B. LOCATION REQUIREMENTS

The model ML-200 dryer requires 18-inches (45.72 cm) of space on each side of the dryer and 24-inches (60.96 cm) of space behind the unit for ease of maintenance. A minimum of 12-inches (30.48 cm) must be allowed between the top of a gas dryer and the ceiling. A ceiling height of 120-inches (304.8 cm) is required for gas dryers, and a ceiling height of 130-inches (330.2 cm) is required for a steam dryers. The dryer must be leveled for proper operation. If shimming is required, put metal shims which are the same size as the base feet. The dryer must be lagged to the floor.

Before installing the dryer, be sure the location conforms to local codes and ordinances.

1.The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.

IMPORTANT: "The dryer must be installed on non-combustible floors only."

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.

12

Image 16
Contents ML-200 Non-Tilting Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASPage Specifications GAS and Steam Models Component IdentificationML-200 Dimensions and Component Location Page Installation Procedures Reassembly of DryerPage Page Location Requirements Fresh AIR Supply Exhaust Requirements Page Compressed AIR Supply System Electrical Information Electrical RequirementsMLG-200 Gas Hp Blower/3 Hp Drive Motor MLS-200 Steam Hp Blower/3 Hp Drive Motor Page GAS Information Type of GAS Latest Edition Page Steam Information System Connections Section H, itemPage Compressed Air Supply Air Pressure Diagram Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions Service SERVICE/PARTS InformationParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers only Adjustments LubricationComponent System Descriptions Tumbler Basket Drive SystemTUMBLER/BASKET AIR Blower Drive SystemSafety Devices Load Door SwitchesSteam Damper Actuator System Troubleshooting No DisplayFailed reversing contactor relay Failed microprocessor controller computer Page Blown 24 VAC control circuit fuse fuse Page For GAS Models only Excessive noise and/or vibration Tumbler basket out of alignment Procedure for Functional Check Replacement Components Page Page Manual Reset HI-LIMIT Instructions P O R T a N TADC113142 1- 04/21/00-8