I. PREPARATION FOR OPERATION/START-UP

The following items should be checked before attempting to operate the dryer:

1.Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.

2.Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed behind the right control box door. In case of 208 VAC or 230 VAC for dryers with sprinkler option verify 1Ø voltage is correct, the supply voltage must match the electric service exactly.

3.GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the dryer data label.

4.GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each sail switch adjustment must be checked to assure that this important safety control is functioning.

5.Check to be sure drive belts between idler pulley and motor pulley have been reconnected.

NOTE: The drive belts were disconnected at factory prior to shipment.

6.GAS MODELS - be sure that ALL gas shut-off valves are in the open position.

7.Be sure ALL side and base panels are on the dryer.

8.Check ALL service doors to assure that they are closed and secure.

9.Be sure lint drawer is securely in place.

NOTE: LINT DRAWER MUST BE ALLTHE WAY IN PLACE TOACTIVATE SAFETY SWITCH OTHERWISE THE DRYER WILLNOT START.

10.Rotate the tumbler (basket) by hand to be sure it moves freely.

11.Check bolts, nuts, screws, terminals, and fittings for security.

12.Check to insure air supply (80 PSI [5.51 bars]) is connected to the dryer.

13.STEAM MODELS - check to insure ALL steam shut-off valves are open.

29

Image 33
Contents ML-200 Non-Tilting Retain This Manual In a Safe Place For Future Reference Foryour Safety Page Table of Contents Section Procedure for Functional Check of Replacement Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Component Identification Specifications GAS and Steam ModelsML-200 Dimensions and Component Location Page Reassembly of Dryer Installation ProceduresPage Page Location Requirements Fresh AIR Supply Exhaust Requirements Page Compressed AIR Supply System Electrical Requirements Electrical InformationMLG-200 Gas Hp Blower/3 Hp Drive Motor MLS-200 Steam Hp Blower/3 Hp Drive Motor Page GAS Information Type of GAS Latest Edition Page System Connections Section H, item Steam InformationPage Compressed Air Supply Air Pressure Diagram Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Shut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsPage Cleaning Routine MaintenanceSteam Dryers only Lubrication AdjustmentsTumbler Basket Drive System Component System DescriptionsTUMBLER/BASKET AIR Blower Drive SystemLoad Door Switches Safety DevicesSteam Damper Actuator System No Display TroubleshootingFailed reversing contactor relay Failed microprocessor controller computer Page Blown 24 VAC control circuit fuse fuse Page For GAS Models only Excessive noise and/or vibration Tumbler basket out of alignment Procedure for Functional Check Replacement Components Page Page P O R T a N T Manual Reset HI-LIMIT InstructionsADC113142 1- 04/21/00-8