American Dryer Corp MDG-50 installation manual Adjustments, Lubrication

Page 40

90 DAYS

Inspect and remove lint accumulation in customer-furnished exhaust duct work system from dryer's internal exhaust ducting.

WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATE A POTENTIALFIRE HAZARD.

WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.

WARNING: INSPECT and REMOVE ANY LINT ACCUMULATION WHICH CAN CAUSE THE BACK DRAFT DAMPER TO BIND OR STICK.

NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of heat circuit safety switches or thermostats.

NOTE: When cleaning the dryer cabinets, avoid using harsh abrasives. Aproduct intended for the cleaning of appliances is recommended.

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing set screws), nonpermanent gas connections (unions, shut-off valves, orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete operational check of ALL safety devices (door switches, lint drawer switch, sail switch, burner, and hi-limit thermostats).

C. LUBRICATION

The motor bearings, idler bearings and under normal or most conditions the tumbler bearings are permanently lubricated. It is physically possible to re-lubricate the tumbler bearings if you choose to do so even though this practice is not necessary. Use Shell Alvania #2 or its equivalent. The tumbler bearings used in the dryer do not have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting which can be obtained elsewhere.

36

Image 40
Contents MDG-50 Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Section Important InformationSafety Precautions Personal Injury or Fire could ResultPage Specifications SpecificationsSpecifications Installation Procedures Unpacking and Setting UPLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Importantventingreminders Electrical Information Electrical RequirementsMust be Provided Odfn Klwh Uhhq Important a Circuit Serving Each Dryer Must be Provided DG-50 GAS GAS Information Injury and Improper Operation of the DryerType of GAS Page Page Preparation for Operation and START-UP Preoperational Tests Preoperational Instructions Page OPL Models Shut Down Instructions Service PartsReturning Warranty Cards SectionRoutine Maintenance CleaningAdjustments LubricationNo L.E.D. light emitting diode display TroubleshootingDrive motor not operating does not start Blower motor not operating does not start Microprocessor computer display reads dSFL Microprocessor controller computer display reads doorNo heat, ignitor sparks, burner goes on and off right away Dryer operates but is taking too long to dry Condensation on main door glass Dryer or scraping noise at basket tumbler areaMain burners are burning with a yellow flame Excessive noise or vibrationDrive motor only not operating Blower motor only not operating Heating unit not operating ALL temperature selectionsDryer operates but is taking too long to dry load Dryer is cycling on hi-limit thermostat Technical Information Data LabelSerial Number Reversing Timer SPIN/DWELL Adjustments Timing LegendProcedure for Functional Check Replacement Components Direct Spark Ignition DSI System 10/30/00-150