D. FRESH AIR SUPPLY

The MDG-50 air supply (makeup air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have a separate makeup air openings for each dryer. Common makeup air openings are acceptable. However, they must be set up in such a manner that the makeup air is distributed equally to the dryers.

EXAMPLE: For a bank of eight (8) dryers, twelve (12) square feet; two (2) unrestricted openings measuring 2 feet by 3 feet (6 square feet each) is acceptable.

IMPORTANT: Makeup air openings should not be located in an area directly near where exhaust vents exit the building.

Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas.

IMPORTANT: Makeup air must be provided from a source free of dry cleaning solvent fumes. Makeup air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to motors and other dryer components.

NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.

11

Image 15
Contents MDG-50 Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Important Information SectionPersonal Injury or Fire could Result Safety PrecautionsPage Specifications SpecificationsSpecifications Unpacking and Setting UP Installation ProceduresLocation Requirements Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Single Dryer Venting Illus. B Multiple Dryer Common Venting ILLUS. D Importantventingreminders Electrical Requirements Electrical InformationMust be Provided Odfn Klwh Uhhq Important a Circuit Serving Each Dryer Must be Provided DG-50 GAS Injury and Improper Operation of the Dryer GAS InformationType of GAS Page Page Preparation for Operation and START-UP Preoperational Tests Preoperational Instructions Page OPL Models Shut Down Instructions Parts ServiceSection Returning Warranty CardsCleaning Routine MaintenanceLubrication AdjustmentsTroubleshooting No L.E.D. light emitting diode displayDrive motor not operating does not start Blower motor not operating does not start Microprocessor controller computer display reads door Microprocessor computer display reads dSFLNo heat, ignitor sparks, burner goes on and off right away Dryer operates but is taking too long to dry Dryer or scraping noise at basket tumbler area Condensation on main door glassExcessive noise or vibration Main burners are burning with a yellow flameDrive motor only not operating Heating unit not operating ALL temperature selections Blower motor only not operatingDryer operates but is taking too long to dry load Dryer is cycling on hi-limit thermostat Data Label Technical InformationSerial Number Timing Legend Reversing Timer SPIN/DWELL AdjustmentsProcedure for Functional Check Replacement Components Direct Spark Ignition DSI System 10/30/00-150