American Dryer Corp ML-310 Phase 7 service manual 105

Page 109

2.Failed overload protector...

a.Incorrect overload setting.

3.Blown drive motor and blower (fan and impellor) motor fuses or overloads.

4.Failed motors (both blower [fan and impellor] motor and drive motor).

5.Failed microprocessor controller (computer).

G.Microprocessor controller (computer) display board light emitting diode (L.E.D.) display reads “BAD PROBE” continuously and the buzzer (tone) sounds every 30-seconds...

1.Fault in microprocessor heating sensing circuit...

a.Failed microprocessor temperature sensor.

b.Failed microprocessor controller (computer) display board.

c.Broken wire or connection between the microprocessor controller (computer) and the microprocessor temperature sensor.

H.Microprocessor controller (computer) L.E.D. display reads “DRY ENABLE” fault...

1.Front or rear doors open.

2.Dryer is not in level position.

3.Broken connection between level switch.

4.Level switches need to be adjusted.

5.Input from Programmable Logic Controller (PLC) is not present...

a.TSX07 does not have supply power.

b.Failed TSX07 PLC.

6.Failed microprocessor controller (computer) input/output (I/O) board.

I.Microprocessor controller (computer) I/O board display reads “FRONT DOORS NOT CLOSED” or “REAR DOORS NOT CLOSED.”

1.Fault (open circuit) in front or rear switch circuit door.

2.One (1) of the front or rear door switches has failed.

3.One (1) of the front or rear door switch contact magnets is either missing or is broken.

4.Broken wire or connection in front door.

105

Image 109
Contents ML-310 Phase Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement ML-310 Reference Guide Base Section Explosion could Result SectionStandards Liquids CleaningAT 80 PSI 5.51 Bars Every 3 Months LubricationDays After Installation and Every 6 Months Thereafter AdjustmentsSpecifications and Dimensions Dimensions Obligation Obligation ENCLOSURE/AIR SUPPLY/EXHAUST Requirements Installation RequirementsElectrical and GAS Requirements Operational Service Check ProcedureDirect Spark Ignition DSI System COMPONENTS/FUNCTIONS Heat SectionVAC Direct Spark Ignition DSI Modules Valves are not Field Repairable First Visual Check Second Visual Check Third Visual Check DSI Ignitor GAP Feeler Gauge Troubleshooting the Direct Spark Ignition DSI SystemPage Page Page First Visual Check Second Visual Check Third Visual Check With a Flame GAP on the Ignitor/Flame-Probe Page Flash Green Continuously Page With a Flame GAP on the Ignitor/Flame-Probe Page Light RED Continuously Page Made of Brass and can be Easily Damaged CreateapotentialsafetyhazardGeneral Overview Steam Coil System OperationPage Page Page Page Sprinkler System Description MAN3488 Page Supplies Before Servicing the Dryer Page Page Tilting System Description Page Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Page Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page Regulator Operation FILTER/REGULATOR AssemblyDoor Systems Manual Doors Automatic Doors Page Page Page Control and Electrical System Ladder Diagram Page Button does not Disable the High Voltage to the Dryer Page ºC + ºC + ºK Page Page Page Page Page Page Tumbler/Drum SECTION. Serious Injury can Result Page Basket Tumbler Drive System Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Page Page Important do not Overtighten Turnbuckle Page Page Page Phase 7 OPL System Diagnostics Inputs RED Outputs Green Fdrc RED L.E.D Lint RED L.E.D 100 101 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 105 106 Dryer operates but is taking too long to dry Excessive noise and vibration 109 Procedure for Functional Check Replacement Components 111 ADC450421 1- 10/03/00-10