5)To install new Microprocessor Controller (computer) input/output (I/O) board, reverse Step #4 thru Step #1.

6)Reestablish electrical power to the dryer. e. Keyboard (touch pad) Replacement

1)Discontinue electrical power to the dryer.

2)Disconnect keyboard (touch pad) ribbon cable from the Phase 7 microprocessor controller (computer) display board.

3)Peel existing keyboard (touch pad) from the door.

4)Remove as much of the remaining adhesive (from the removed keyboard [touch pad]) as possible.

5)Install and adhere new keyboard (touch pad).

6) Reestablish electrical power to the dryer. f. Switch Replacement

1) Discontinue electrical power to the dryer.

2) Mark and identify the wires that will be removed for proper reinstallation.

3)Remove wires.

4)To remove a contact block, loosen and remove the mounting screw.

NOTE: Contact Block #1 and Contact Block #2 is normally closed (N.C.) while Contact Block #3 and Contact Block #4 is normally open (N.O.).

5)To remove or replace operator, loosen the two (2) screws that hold the switch body away from the door.

6)Quarter turn the operator (in the direction shown in the above illustration) and remove.

7)Reinstall the wires removed in Step #3.

8) Reestablish electrical power to the dryer. g. Switch Bulb Replacement

1) Discontinue electrical power to the dryer.

2) Unscrew clear lens shield.

3) Unscrew colored lens.

4) Remove diffuser.

8 4

Image 88
Contents ML-310 Phase Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement ML-310 Reference Guide Base Section Section Explosion could ResultStandards Cleaning LiquidsAT 80 PSI 5.51 Bars Lubrication Every 3 MonthsAdjustments Days After Installation and Every 6 Months ThereafterSpecifications and Dimensions Dimensions Obligation Obligation Installation Requirements ENCLOSURE/AIR SUPPLY/EXHAUST RequirementsOperational Service Check Procedure Electrical and GAS RequirementsHeat Section Direct Spark Ignition DSI System COMPONENTS/FUNCTIONSVAC Direct Spark Ignition DSI Modules Valves are not Field Repairable First Visual Check Second Visual Check Third Visual Check Troubleshooting the Direct Spark Ignition DSI System DSI Ignitor GAP Feeler GaugePage Page Page First Visual Check Second Visual Check Third Visual Check With a Flame GAP on the Ignitor/Flame-Probe Page Flash Green Continuously Page With a Flame GAP on the Ignitor/Flame-Probe Page Light RED Continuously Page Createapotentialsafetyhazard Made of Brass and can be Easily DamagedSteam Coil System Operation General OverviewPage Page Page Page Sprinkler System Description MAN3488 Page Supplies Before Servicing the Dryer Page Page Tilting System Description Page Page Page Page Page AIR JET Assembly Page Blower Squirrel Cage Fan Motor Assembly Page Page Important do not Overtighten V-BELTS Important do not Overtighten V-BELTS Page Page FILTER/REGULATOR Assembly Regulator OperationDoor Systems Manual Doors Automatic Doors Page Page Page Control and Electrical System Ladder Diagram Page Button does not Disable the High Voltage to the Dryer Page ºC + ºC + ºK Page Page Page Page Page Page Tumbler/Drum SECTION. Serious Injury can Result Page Basket Tumbler Drive System Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Page Page Important do not Overtighten Turnbuckle Page Page Page Phase 7 OPL System Diagnostics Inputs RED Outputs Green Fdrc RED L.E.D Lint RED L.E.D 100 101 Troubleshooting Drive motor is not operating does not start Impellor fan motor is not operating does not start 105 106 Dryer operates but is taking too long to dry Excessive noise and vibration 109 Procedure for Functional Check Replacement Components 111 ADC450421 1- 10/03/00-10