Amana W10150612B, W10150613B installation instructions Plan Vent System, Determine vent path

Page 12

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

 

B

 

C

 

D

A

E

 

F

 

G

 

B

 

H

A. Dryer

E. Clamps

B. Elbow

F. Rigid metal or flexible metal vent

C. Wall

G. Vent length necessary to connect elbows

D. Exhaust hood

H. Exhaust outlet

Standard exhaust installation with rigid metal or flexible metal vent

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A.Over-the-top installation (also available with one offset elbow)

B.Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section of the Dryer User Instructions.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch

Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most direct path outdoors.

Plan the installation to use the fewest number of elbows and turns.

When using elbows or making turns, allow as much room as possible.

Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.

12

Image 12
Contents 29 73.7 CM Electric Dryer Installation Instructions Tools and Parts Location RequirementsParts supplied Parts neededInstallation Clearances Mobile Home Additional Installation RequirementsElectrical Requirements U.S.A It is your responsibilityIf connecting by direct wire Electrical ConnectionIf your outlet looks like this Electrical Requirements Canada CanadaPower Supply Cord Direct Wire Install strain reliefStyle 1 Power supply cord strain relief Electrical Connection U.S.A. OnlyWire connection Power Supply Cord Style 2 Direct wire strain reliefWire connection Direct Wire Remove center silver-colored terminal block screwUnder the outer terminal block screws hooks facing right Squeeze hooked ends together. Tighten screwsSecure cover with hold-down screw You have completed your electrical connections. Now go toOptional 3-wire connection If using an existing vent system Venting RequirementsIf this is a new vent system Vent material Special provisions for mobile home installations Plan Vent SystemDetermine vent path Install Vent System Install Leveling LegsVent system chart Level DryerReverse Door Swing Optional Reversible Large Side-Swing DoorReversible Super Wide Side-Swing Door Complete Installation U.S.ACanada If the dryer will not start, check the followingSécurité DE LA Sécheuse Exigences d’emplacement Outillage et pièces’installation dans une maison mobile exige Spécifications électriques Canada’est à l’utilisateur qu’incombe la responsabilité de Espacement requisExigences concernant l’évacuation En cas dutilisation du système dévacuation existantPlanification du système d’évacuation Le clapet incliné de type boîte ci-dessous est acceptableInstallation du système d’évacuation Installation des pieds de nivellementDéterminer litinéraire dacheminement du conduit Une réduction de la longévité de la sécheuseMise à niveau de la sécheuse Raccordement du conduit d’évacuationInversion du sens d’ouverture de la porte Facultatif Grande porte réversible à pivotement latéralAchever l’installation Si la sécheuse ne démarre pas, vérifier ce qui suitW10150612B SP PN W10150613B Tous droits réservés