Maytag W10296136A-SP Electrical Requirements, It is your responsibility, For mobile home use

Page 6

Electric Dryer Power Hookup - Canada Only

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility:

■■ To contact a qualified electrical installer.

■■ To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

■■ To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.

■■ This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure wall receptacle is within reach of dryer’s final location.

4-wire receptacle (14-30R)

■■ Do not use an extension cord.

If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 3394208. For further information, please reference the “Assistance or Service” section of the “Dryer User Instructions.”

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Install Leveling Legs

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

1.To avoid damaging the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. See illustration.

2.Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.

4.Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.

5.Place a carton corner post under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

6.Once connection is made and dryer is in final location, remove corner posts and cardboard.

For mobile home use

Gas dryers must be securely fastened to the floor.

3.Examine the leveling legs. Find the diamond marking.

Mobile home installations require a Mobile Home Installation Hold-down Kit. For ordering information please reference the “Dryer User Instructions.”

6

Image 6
Contents Dryer Safety Table of Contents Table des matièresPage Important Safety Instructions Installation Requirements Tools and PartsLocation Requirements Installation Spacing Installation clearancesWide Models Dryer Dimensions Installation spacing for recessed area or closetElectrical Requirements It is your responsibilityFor mobile home use Gas type GAS Dryer Power HookupGas Supply Requirements Gas supply lineVenting Requirements Plan Vent System Vent System Chart Alternate installations for close clearancesSpecial provisions for mobile home installations Vent System Chart 29 Wide Long Vent Models OnlyLevel Dryer Install Vent SystemComplete Installation Make Gas ConnectionReversible Large Side Swing Door Reverse Door Swing OptionalWide Models Reversible Super Wide Side-Swing DoorReversible Side-Swing Door Sécurité DE LA Sécheuse Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Page Exigences Dinstallation Exigences demplacementOutillage et Pièces Espacements dinstallation Espacement pour une installationEspacement requis Spécifications Électriques Cest à lutilisateur quincombe la responsabilité deNe pas utiliser de câble de rallonge Spécifications de lalimentation en gaz Installation DES Pieds DE NivellementRaccordement Dune Sécheuse À GAZ Pour utilisation en maison mobileExigences concernant le raccordement au gaz Canalisation de gazCanalisation darrivée de gaz de la sécheuse Caractéristiques dalimentation du brûleurÉvacuation Exigences concernant lévacuationInstallations dévacuation recommandées Installations dévacuation facultativesPlanification du système dévacuation Déterminer litinéraire dacheminement du conduit Installation du circuit dévacuationDispositions spéciales pour les maisons mobiles Tableau des systèmes dévacuationRaccordement au gaz Raccordement du conduit devacuation Achever linstallationRéglage de laplomb de la sécheuse Si la sécheuse ne démarre pas, vérifier ce qui suitGrande porte réversible à pivotement latéral Inversion du sens douverture De la porte facultatifModèles de 29 de largeur Porte réversible extra-large à pivotement latéralPorte à ouverture latérale réversible W10296135A W10296136A-SP