Maytag W10296136A-SP, W10296135A, MGDC500VW installation instructions Plan Vent System

Page 9

■■ Must be fully extended and supported when the dryer is in its

 

final location.

 

 

■■

Remove excess flexible metal vent to avoid sagging

 

and kinking that may result in reduced airflow

and

poor

 

performance.

 

 

■■

Do not install flexible metal vent in enclosed

walls,

ceilings,

 

or floors.

 

 

Plan Vent System

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

■■ The total length of flexible metal duct shall not exceed

7¾ ft. (2.4 m).

Elbows:

■■ 45° elbows provide better airflow than 90° elbows.

GoodBetter

Clamps:

■■ Use clamps to seal all joints.

■■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct

A

A.Dryer

B.Elbow

C.Wall

D.Exhaust hood

E.Clamps

B

C

D

E

F

G

 

B

I

H

F. Rigid metal or flexible

metal vent

G.Vent length necessary to connect elbows

H.Exhaust outlet

I.Optional side exhaust outlet (27" wide models only)

and catch lint. Do not use duct tape.

Clamp

 

Exhaust:

 

Recommended hood styles.

Acceptable hood style.

B

C

 

4"

A

(102 mm)

 

4"

2½"

(102 mm)

(64 mm)

4"

 

(102 mm)

 

A.Louvered hood style

B.Box hood style

C.Angled hood style is acceptable

■■ An exhaust hood should cap the vent to keep rodents and insects from entering the home.

■■ Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

■■ Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Optional exhaust installations:

27" Wide Models can be converted to exhaust out the right side, left side, or through the bottom. Each kit includes step-by- step instructions. For further information, please reference the “Assistance or Service” section of the “Dryer User Instructions.”

9

Image 9
Contents Table of Contents Table des matières Dryer SafetyPage Important Safety Instructions Installation Requirements Tools and PartsLocation Requirements Wide Models Dryer Dimensions Installation clearancesInstallation Spacing Installation spacing for recessed area or closetElectrical Requirements It is your responsibilityFor mobile home use Gas Supply Requirements GAS Dryer Power HookupGas type Gas supply lineVenting Requirements Plan Vent System Special provisions for mobile home installations Alternate installations for close clearancesVent System Chart Vent System Chart 29 Wide Long Vent Models OnlyComplete Installation Install Vent SystemLevel Dryer Make Gas ConnectionWide Models Reverse Door Swing OptionalReversible Large Side Swing Door Reversible Super Wide Side-Swing DoorReversible Side-Swing Door Votre sécurité et celle des autres est très importante Sécurité DE LA SécheuseImportantes Instructions DE Sécurité Page Exigences Dinstallation Exigences demplacementOutillage et Pièces Espacements dinstallation Espacement pour une installationEspacement requis Spécifications Électriques Cest à lutilisateur quincombe la responsabilité deNe pas utiliser de câble de rallonge Raccordement Dune Sécheuse À GAZ Installation DES Pieds DE NivellementSpécifications de lalimentation en gaz Pour utilisation en maison mobileCanalisation darrivée de gaz de la sécheuse Canalisation de gazExigences concernant le raccordement au gaz Caractéristiques dalimentation du brûleurExigences concernant lévacuation ÉvacuationInstallations dévacuation recommandées Installations dévacuation facultativesPlanification du système dévacuation Dispositions spéciales pour les maisons mobiles Installation du circuit dévacuationDéterminer litinéraire dacheminement du conduit Tableau des systèmes dévacuationRéglage de laplomb de la sécheuse Achever linstallationRaccordement au gaz Raccordement du conduit devacuation Si la sécheuse ne démarre pas, vérifier ce qui suitModèles de 29 de largeur Inversion du sens douverture De la porte facultatifGrande porte réversible à pivotement latéral Porte réversible extra-large à pivotement latéralPorte à ouverture latérale réversible W10296135A W10296136A-SP