Dakota Digital MMX-6 operation manual Appendix C, Sound Velocities of some Common Materials

Page 47

MMX-6 DL Ultrasonic Thickness Gauge

APPENDIX C

Sound Velocities of some Common Materials

M a te ria l

s o u n d v e lo c ity

 

in /u s

 

m /s

A lu m in u m

0 .2 5 0

6 3 5 0

B is m u th

0 .0 8 6

2 1 8 4

B ra s s

0 .1 7 3

4 3 9 4

C a d m iu m

0 .1 0 9

2 7 6 9

C a s t Iro n

0 .1 8 0 (a p p rx )

4 5 7 2

C o n s ta n ta n

0 .2 0 6

5 2 3 2

C o p p e r

0 .1 8 4

4 6 7 4

E p o xy re s in

0 .1 0 0 (a p p rx )

2 5 4 0

G e rm a n s ilv e r

0 .1 8 7

4 7 5 0

G la s s , c ro w n

0 .2 2 3

5 6 6 4

G la s s ,flin t

0 .1 6 8

4 2 6 7

G o ld

0 .1 2 8

3 2 5 1

Ic e

0 .1 5 7

3 9 8 8

Iro n

0 .2 3 2

5 8 9 3

L e a d

0 .0 8 5

2 1 5 9

M a g n e s iu m

0 .2 2 8

5 7 9 1

M e rc u ry

0 .0 5 7

1 4 4 8

N ic k e l

0 .2 2 2

5 6 3 9

N ylo n

0 .1 0 2 (a p p rx )

2 5 9 1

P a ra ffin

0 .0 8 7

2 2 1 0

P la tin u m

0 .1 5 6

3 9 6 2

P le x ig la s s

0 .1 0 6

2 6 9 2

P o lys tyre n e

0 .0 9 2

2 3 3 7

P o rc e la in

0 .2 3 0 (a p p rx )

5 8 4 2

P V C

0 .0 9 4

2 3 8 8

Q u a rtz g la s s

0 .2 2 2

5 6 3 9

R u b b e r, v u lc a n iz e d

0 .0 9 1

2 3 1 1

S ilv e r

0 .1 4 2

3 6 0 7

S te e l, c o m m o n

0 .2 3 3

5 9 1 8

S te e l, s ta in le s s

0 .2 2 3

5 6 6 4

S te llite

0 .2 7 5 (a p p rx )

6 9 8 5

T e flo n

0 .0 5 6

1 4 2 2

T in

0 .1 3 1

3 3 2 7

T ita n iu m

0 .2 4 0

6 0 9 6

T u n g s te n

0 .2 1 0

5 3 3 4

Z in c

0 .1 6 6

4 2 1 6

W a te r

0 .0 5 8

1 4 7 3

43

Image 47
Contents Dakota Ultrasonics Dakota Ultrasonics Contents Disclaimer Very Important Introduction Blank Keypad OperationDakota Ultrasonics MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Display Dakota Ultrasonics Is currently operating in echo-echo Thru-paint/coating mode Transducer Making Measurements Dakota Ultrasonics Condition and Preparation of Surfaces Performing a Probe-Zero Probe ZeroCalibration Dakota Ultrasonics Calibration to a known thickness Dakota Ultrasonics Calibration to a known velocity Dakota Ultrasonics Two Point Calibration Units in/mm MMX-6 DL Modes Changing Units in / MMBack light Using The Back LightScan Mode Alarm Mode Using Scan ModeUsing the Beeper Dual-Multi Mode RS232 Serial Port & The Data Logger Connecting To a ComputerUsing The Data Logger Using the Data Logger Clearing a Storage Location Clearing an Entire File Sending All Files to a Computer Clearing all FilesPrinting a File Transducer Selection MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Blank Keypad Product Specifications PhysicalPower Source Appendix aMeasuring hot surfaces Appendix BApplication Notes Measuring pipe and tubing Measuring laminated materials Measuring Through Paint & Coatings Blank Sound Velocities of some Common Materials Appendix CBlank Warranty Statement Warranty Information