The Transducer

The transducer is the "business end" of the MMX-6 DL. It transmits and receives ultrasonic sound waves that the MMX-6 DL uses to calculate the thickness of the material being measured. The transducer connects to the MMX-6 DL via the attached cable, and two coaxial connectors. When using transducers manufactured by Dakota Ultrasonics, the orientation of the dual coaxial connectors is not critical: either plug may be fitted to either socket in the MMX-6 DL.

The transducer must be used correctly in order for the MMX-6 DL to produce accurate, reliable measurements. Below is a short description of the transducer, followed by instructions for its use.

This is a bottom view of a typical transducer. The two semicircles of the wearface are visible, as is the barrier separating them. One of the semicircles is responsible for conducting ultrasonic sound into the material being measured, and the other semicircle is responsible for conducting the echoed sound back into the transducer. When the transducer is placed against the material being measured, it is the area directly beneath the center of the wearface that is being measured.

10

Image 14
Contents Dakota Ultrasonics Dakota Ultrasonics Contents Disclaimer Very Important Introduction Blank Operation KeypadDakota Ultrasonics MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Display Dakota Ultrasonics Is currently operating in echo-echo Thru-paint/coating mode Transducer Making Measurements Dakota Ultrasonics Condition and Preparation of Surfaces Probe Zero Performing a Probe-ZeroCalibration Dakota Ultrasonics Calibration to a known thickness Dakota Ultrasonics Calibration to a known velocity Dakota Ultrasonics Two Point Calibration MMX-6 DL Modes Changing Units in / MM Units in/mmBack light Using The Back LightScan Mode Using Scan Mode Alarm ModeUsing the Beeper Dual-Multi Mode Connecting To a Computer RS232 Serial Port & The Data LoggerUsing The Data Logger Using the Data Logger Clearing a Storage Location Clearing an Entire File Clearing all Files Sending All Files to a ComputerPrinting a File Transducer Selection MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Blank Appendix a Product Specifications PhysicalPower Source KeypadMeasuring hot surfaces Appendix BApplication Notes Measuring pipe and tubing Measuring laminated materials Measuring Through Paint & Coatings Blank Appendix C Sound Velocities of some Common MaterialsBlank Warranty Information Warranty Statement