The UP arrow key has three functions. When the MMX-6 DL is in calibration mode, this key is used to increase numeric values on the display. An auto-repeat function is built in, so that when the key is held down, numeric values will increment at an increasing rate. When MODE is activated, the UP arrow key scrolls through the various features and settings of the MMX-6 DL. When the data logging feature has been activated by pressing the MEM key, the UP arrow is used to scroll through the various files, storage locations, and functions of the data logger. Refer to page 28 for further information regarding the use of the UP arrow key and the data logger.

The DOWN arrow key has three functions. When the MMX-6 DL is in the CAL mode, this key is used to decrease numeric values on the display. An auto-repeat function is built in, so that when the key is held down, numeric values will decrement at an increasing rate. When MODE is activated, the DOWN arrow scrolls through the various features and settings of the MMX-6 DL. When the data logging feature has been activated by pressing the MEM key, the UP arrow is used to scroll through the various files, storage locations, and functions of the data logger. Refer to page 28 for further information regarding the use of the DOWN arrow key and the data logger.

5

Image 9
Contents Dakota Ultrasonics Dakota Ultrasonics Contents Disclaimer Very Important Introduction Blank Keypad OperationDakota Ultrasonics MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Display Dakota Ultrasonics Is currently operating in echo-echo Thru-paint/coating mode Transducer Making Measurements Dakota Ultrasonics Condition and Preparation of Surfaces Performing a Probe-Zero Probe ZeroCalibration Dakota Ultrasonics Calibration to a known thickness Dakota Ultrasonics Calibration to a known velocity Dakota Ultrasonics Two Point Calibration Units in/mm MMX-6 DL Modes Changing Units in / MMUsing The Back Light Scan ModeBack light Alarm Mode Using Scan ModeUsing the Beeper Dual-Multi Mode RS232 Serial Port & The Data Logger Connecting To a ComputerUsing The Data Logger Using the Data Logger Clearing a Storage Location Clearing an Entire File Sending All Files to a Computer Clearing all FilesPrinting a File Transducer Selection MMX-6 DL Ultrasonic Thickness Gauge Dakota Ultrasonics Blank Power Source Product Specifications PhysicalAppendix a KeypadAppendix B Application Notes Measuring pipe and tubingMeasuring hot surfaces Measuring laminated materials Measuring Through Paint & Coatings Blank Sound Velocities of some Common Materials Appendix CBlank Warranty Statement Warranty Information