Section 6
Programming
From the ZR310 Configuration Screen, you may set the programmable features. Programmable feature in the ZR310 are divided into three categories:
•System Programmable Fields
•User Programmable Fields
•Diagnostic Tests
System Programmable Fields
The following subparagraphs describe the system commands available for the ZR310.
Program Mode Access Code
The program mode access code is a number between 1000 and 32000.
Morse ID interval, Speed, and Frequency
You can program the Morse Code station identification in frequency, interval and speed. The following table outlines the programmable range and the default settings of each.
Frequency
Interval
Speed
Table
Programmable Range | Default |
1200Hz | |
15 Min | |
22 wpm |
Each user on the ZR310 has its own independent station ID timer that is accurate to one second per interval. When the station ID is sent, the timer is reset. The call is transmitted on the first dispatch message after the timer has expired.
During normal dispatch, the minimum character speed will be 15 wpm. This allows the "List" functions (using Morse code as a format) to be sent at very slow speed, while maximizing airtime use during normal dispatch.
Courtesy Tone Frequency
The courtesy tone is used for courtesy tone and prompt beeps. It is programmable in frequency from 400 to 2500 Hz, and the default setting is 1000 Hz.
A possible reason to change the frequency could be to differentiate between
System ID User Number
A user number may be assigned as the "System ID user number" so that the repeater will identify every ID interval (1 to 99 minutes).
Before sending the System ID, the following conditions must be met:
•The system ID interval timer must expire (adjustable 1 to 99 minutes).
•The ZR310 must be inactive (TPL/DPL Decode LED off).
•The System ID must have a number programmed.
March, 1993 | Section |