Furuno FI-504 manual Selecting Apparent or True Wind Angle, Wind Speed

Page 16

1. OPERATION

1.5Selecting Apparent or True Wind Angle, Wind Speed

You can show wind angle and wind speed in apparent or true wind. The apparent wind is the actual flow of air acting upon a sail, or the wind as it appears to the sailor. True wind is the wind seen by a stationary ob- server in velocity and direction.

WIth a wind angle or wind speed indication displayed, press the APP/ TRUE key to change the wind angle or wind speed to apparent and true alternately. A beep sounds after the change is completed. (Wind angle and wind speed displays are mutually changed.) True wind requires boat speed input. If there is no speed input three dashes appear.

APP

KT

APP

5.0HI

135HI

APP

 

APP

TRUE

TRUE

TRUE

KT

TRUE

9.6

157

 

HI

HI

Apparent and true

Apparent and true

wind speeds

wind angles

1.6Resetting Counters and Indications

You can reset the following counters and indications:

Trip distance

Course made good

Distance made good

Average speed

Average SOG

Maximum speed

Maximum SOG

Average heading

Maximum true wind speed

Select the applicable display and press and hold down the SELECT/ CLEAR key. A short beep sounds, the counter or indication flashes twice and then a long beep sounds to indicate that resetting is completed.

8

Image 16
Contents FI-504 Multi Instrument 00016733410 Important Notices Safety Instructions Table of Contents Foreword Word to the Owner of the FI-504System Configuration Standalone configurationNmea 2000 network Nmea 2000 SensorsOperation Operating Controls, Display LayoutTurning the Power On/Off Adjusting Brilliance and ContrastSelecting a Display DepthDepth category Display descriptionSpeed category Timer category Wind categoryHeading category Navigation categoryAutopilot category Environment categoryEngine category Resetting Counters and Indications Selecting Apparent or True Wind Angle, Wind SpeedAlarms MAX38.9 LO9.7 12.2Alarm description Timers Count-up timerCount-down timers How to set the timersOperation MAINTENANCE, Troubleshooting Preventive MaintenanceTroubleshooting Installation Equipment ListsStandard supply Optional supplyMounting Surface mount 1 Fix instrument from front panelSurface mount 2 Fix instrument from rear panel Wiring Multi-instrument configurationJunction box option Terminal resistor Sensor FI-50x FI-50x FI-50xSetting Up Setup1 menuOff OFF SPD RES LOC Setup2 menu OFFSetup2 menu items Press the SELECT/CLEAR Specifications Packing フラッシュマウントキット Jul.2407 R.Esumi Jul.2407 R.Esumi Jul.2407 R.Esumi Instrument タッピンネジ用穴(4ヵ所) For tapping screws 4 pcs